PCL 600
Operators Manual
v 2.0
38
8 Calibration
This chapter describes the calibration procedures and will guide you through the process. In the ‘Service
menu you will find the following calibration dialogs:
Calibrate
clamps
Calibrate active frame
Calibrate
tool
8.1
Tools and material
The calibration column supplied by HGG is used for the first two of these procedures. For the plasma torch
calibration you will need a flat bar that complies with the following conditions:
Web size = 200 to 300 mm
Thickness = 10 to 30 mm
Maximum deflection* = 0.5 mm/m
Maximum overall deflection = 3 mm
Maximum twisting* = 0.1°
* For an explanation of these terms, see chapter 1.3 Material
specifications.
You will also need the calibration column and the calibration pin
for the plasma torch.
You will need the following tools to make the measurements:
Pair of calipers
Set of Allen keys
Tape measure