10 Series Owner’s Manual
ENGINEERING SPECIFICATIONS
10 SERIES
13MAQ 13BEQ
*
13MXQ
13MDQ
12AMQ
12APQ
** ***
12AKQ 12AJQ
****
Tannin (ppm)
0
0
0
0-2
0 0 0
0
Sulfur (ppm) – SulfurStat
0 0 0 0 0 0-5** 0 0
Iron (ppm) – ferrous – clear water
0 0 12 0 12 2-12** 15 5
Maximum Compensated Hardness
90 90 110
90
90 90 90
60
Maximum Chlorine (ppm)
1
3
0
0
0 0 0
0
Minimum pH
7
7
7
7
7 7 7
6.3
Filtration – nominal rating (microns)
20
25
20
20
20 20 20
20
#1 Salt –5850 grains per lb of salt
(lbs./capacity)
1/5,850 1/5,850 1.6/9,360
NA
1/5,850
NA
NA
NA
#2 Salt –5163 grains per lb of salt
(lbs./capacity)
2.7/13,890 2.7/13,890 4.2/21,680
NA
2.7/13,890
NA
NA
2.7/13,890
#3 Salt –4679 grains per lb of salt
(lbs./capacity)
6.2/28,730
6.2/28,730
9.6/44,840
8.5/28,730
6.2/28,730 6.2/28,730 6.2/28,730
6.2/28,730
#4 Salt –3828 grains per lb of salt
(lbs./capacity)
9.3/35,300
9.3/35,300
14.4/55,090
10.7/35,300
9.3/35,300 9.3/35,300 9.3/35,300
9.3/35,300
Media Amount Compartment #1
1.5 lbs.
2.0 lbs.
1.5 lbs.
1.5 lbs.
NA
NA
NA
NA
Media Amount Compartment #2
Empty
.4 cu.ft.
.6 cu.ft.
.3 cu.ft.
6 lbs.
27 lbs.
.4 cu.ft.
.4 cu.ft.
Media Amount Compartment #3
1.06 cu.ft.
1.06 cu.ft.
1.06 cu.ft.
1.06 cu.ft.
1.06 cu.ft.
1.06 cu.ft.
1.06 cu.ft.
1.06 cu.ft.
Backwash Rate (gpm) @ min. water pressure
2.4
3
2.4
2.4
5
***Empty
7
7
Brine Line Flow Control Refill (gpm)
.5 .5 .5 .5 .5
.5
.5 .5
Water Pressure (min-max psi)
20-120 20-120 20-120 20-120 20-120
30-120
30-120 30-120
Flow Rate @ 25 psi drop
19.5 19.5 17
17
23
19.6
19.6 20.5
Flow Rate @ 15 psi drop
11 13 10.5
10.5
11.2 10.6 10.6 12.5
Pressure Drop @ Flow Rate Of 4 gpm
6.5 psi
8.5 psi
8.5 psi
8.5 psi
3.2 psi
6 psi
6 psi
7 psi
(#1 Salt Setting) total length of reg. Min / gal
12/13.5 12/16 12/13.5
NA
12/24
NA
NA
NA
(#2 Salt Setting) total length of reg. Min / gal
18/16.5 18/19 26/20.5
NA
18/27
NA
NA
23/70
(#3 Salt Setting) total length of reg. Min / gal
38/26.5 38/29.5 58/36.5 47/31
38/37
44/80
44/80
44/80
(#4 Salt Setting) total length of reg. Min / gal
56/35.5 56/38 74/44.5 64/39.5 58/56
61/89
61/89 61/89
Shipping weight (lbs.)
135
152
168
152
140 167 160
180
Bacteriostatic – KDF® Process Media – Listed
With The U.S. EPA As A Bacteriostatic Device.
U.S. EPA #54369-OH-001
YES YES YES YES YES
YES
YES YES
Valve Inlet/Outlet 1"
Drain Line (Minimum I.D.) ½ "
Water Temperature (Min-Max) 40-120 ºF
Height (inches) 38"
Floor Space (inches) 14" x 28"
Salt storage capacity: 200 lbs, 90kg
Brine & Rinse total: .65 gpm
Brine Draw: .25 gpm
Rinse: .4 gpm
Electrical rating: 115V, 60 cycle.
*Municipally Supplied Chlorinated Water Only.
**Must Have A Minimum of 2 ppm Iron and a Minimum of 200 ppm TDS.
***Unit Has No Backwash Flow Control Button Or Retainer. Must Have A
Minimum Of 7 gpm @ 30 psi Available For Proper Backwash.
****Calcite Will Add Additional Hardness
To Water Before Softening.
Rate Of Flow Must Be Verified At The
End Of ½" ID Drain Line.
Any Hardness Over 10 gpg Will
Increase The Chance Of Calcium
Carbonate Precipitation. As The
Hardness Increases So Does The Chance
Of This Precipitation.
Must Use Citric Acid to Regenerate
Along With Salt.
•
=
Iron Reduction To .3 ppm Or Less.
•
=
When Adding Media In The Field,
Check For Proper Settings (See
Specifications, Above.)
•
=
Regeneration Every 96 Hours Is
Required When Iron Is Present In
The Raw Water Supply. Use Salt
Setting #3 Or #4.
Содержание Watermax 10 Series
Страница 1: ...10 Series Owner s Manual...
Страница 37: ...10 Series Owner s Manual 35 NOTES...
Страница 38: ...NOTES...
Страница 39: ...10 Series Owner s Manual 37 NOTES...