10 Series Owner’s Manual
TROUBLE-SHOOTING
PROBLEM
CAUSE ACTION
Appliance is plumbed in backward.
Check that appliance is plumbed properly.
(See Fig 1, pg. 3.)
Sensor not receiving signal from
Remove sensor from bypass
Magnet. (See Fig. 7, pg. 23.)
housing. Test with magnet on each
flat
side
of
sensor.
One
side
should
cause
the
light
to
glow.
The
other
will
not.
If
light
glows,
check
turbine.
If
no
light,
replace
sensor.
Turbine is jammed.(See Fig. 7, pg. 23.) Remove bypass valve and clear
debris from turbine.
Light blinks when water is
There is a leak in your household
Repair the leak.
not being used. (Fig. 2, p. 5)
plumbing system.
Light on steady. (Fig. 2, p. 5)
Turbine stopped over sensor.
Run water. Verify flashing light.
Read-out lights do not glow.
Electric cord is unplugged.
Plug in transformer. (See Fig. 1, pg. 3.)
No electric power at outlet.
Check power source. Make sure
Outlet
is
not
controlled
by
a
switch.
Defective transformer.(See Fig. 3, p. 18) Test with volt meter for 12VAC at
control. If less than 10 VAC or greater
than 14 VAC, replace transformer.
Defective circuit board.
With 12V AC present at control,
Replace
computer
control.
High ambient temperature. If
See Engineering Specifications, pg. 12.
temperature
exceeds
120°F,
display
will blank out. This does not affect the
operation
of
the
controller.
Appliance stays in
Defective magnet disk.
Replace magnet disk. (See Fig. 8, p. 25.)
regeneration.
Cycle
display
remains
“going
to _?_”.
Foreign object in valve body.
Remove foreign objects from valve
body.
(See
Fig.
5,
p.
20.)
Содержание Watermax 10 Series