background image

10 Series Owner’s Manual 

 

 

INSTALLATION AND START UP 

1.  Place the 10 Series in the desired location. Turn off the electricity and/or 

water supply to the water heater.  Make sure the inlet, outlet and drain 
connections meet the applicable local codes.  Check arrows on the bypass 
valve to be sure the water flows in proper direction. 

CAUTION:  Do not 

plumb the appliance in backwards.

 

2.  The drain hose must be a minimum of 1/2" I.D. tubing and should make 

the shortest run to a suitable drain. 

3.  Connect the salt tank to the valve head with the flexible 3/8" plastic tube 

included with the system. Be sure to insert the plastic insert in the end of 
the brine tube.  (See Figure 13, page 32.) 

Connect the Overflow Line to the brine tank.  If the brine tank is filled 
with too much water, or if there is a malfunction, an overflow line will 
direct excess water to drain. 
 
Insert the 2 pc. Overflow fitting into the outside of the cabinet and attach 
it with the plastic thumb nut.  Connect ½" I.D. tubing (not supplied) 
between the overflow fitting and a suitable waste receptor.  Maintain a 
minimum of 2" (50 mm) air gap between the drain line and the flood 
level rim of the waste receptor to prevent back siphoning.  This is a 
gravity drain.  The overflow line must end at a drain that is at least 3" 
lower than the bottom of the overflow fitting. 
 

4.  Attach the drain line.  Route the drain line to a floor drain, laundry tub or 

other suitable waste receptor.  Maintain a minimum of 2" (50 mm) air 
gap between the drain line and the flood level rim of the waste receptor 
to prevent back siphoning. 

5.  Place the appliance in the bypass position and turn on the main water 

supply.  Open the nearest cold water faucet to flush the plumbing of any 
excess soldering flux, air, or any other foreign material. 

6.  Close the faucet and check for leaks.  If leaks are found, turn off the main 

water supply and open the nearest cold water faucet to depressurize the 
lines.  Close the faucet to eliminate siphoning action.  Repair leaks.  
Place the bypass in the “service” position.  Slowly open the main water 
supply valve and fill the WaterMax.  Then open the nearest cold water 
faucet to purge air out of the appliance.  Close faucet. 

7.  Connect transformer power cord to the back of the controller. 
8.  Plug in transformer. 
9.  Program the Systems Control as outlined on Page 5-11. 

10.  Add water to the brine tank.  Fill to a minimum of 2" above the grid 

plate.  Make sure that the salt dosage is set as recommended for the 
application.  After the first regeneration, the appliance will automatically 
refill the correct amount of water into the brine tank. 

11.  Initiate a manual regeneration and inspect for proper operation.  Allow 

the appliance to draw all the water out of the brine cabinet until the air 
check sets.  Then advance to Brine Refill position by using Change & 
Select buttons simultaneously.  Let the tank fill with proper amount of 
water.  The controller will then step the valve to the Home position. 

Содержание Watermax 10 Series

Страница 1: ...10 Series Owner s Manual...

Страница 2: ...LUG ASSEMBLY 29 PARTS WATERMAX DRAIN END CAP ASSEMBLY 30 PARTS WATERMAX SAFETY SHUTOFF ASSEMBLY 31 PARTS BRINE VALVE ELBOW INSTALLATION INSTRUCTIONS 32 PARTS BRINE CABINET DATA 33 25 YEAR LIMITED RESI...

Страница 3: ...mix 2 Allow the appliance to regenerate at a time when the water is not being used If you have more than one appliance allow two hours between each regeneration 3 Protect your WaterMax including the d...

Страница 4: ...on ts 1 Do not install if the above items are not satisfactory 2 Do not install if incoming or outlet piping water temperature exceeds 120 F 3 Do not allow soldering torch heat to be transferred to va...

Страница 5: ...aste water In placing the 10 Series consider the following Install the 10 Series ahead of the water heater to prevent build up of hard water deposits in the water heater This placement will maintain t...

Страница 6: ...loor drain laundry tub or other suitable waste receptor Maintain a minimum of 2 50 mm air gap between the drain line and the flood level rim of the waste receptor to prevent back siphoning 5 Place the...

Страница 7: ...n Test the water at the test port to verify soft water 15 Place covers on both cabinets When using potassium chloride as an alternative to sodium chloride increase the hardness setting by 12 Note we d...

Страница 8: ...to accomplish various functions D CHANGE DIGIT FUNCTION Used to change values of parameters that can be set Used in conjunction with SELECT DIGIT button Used simultaneously with CHANGE DIGIT button t...

Страница 9: ...MER MODE Will regenerate based on frequency Example every 2 days or as specified up to 12 days Time of regeneration can be set MODE 2 PATENTED SAVEMATIC DEMAND DELAYED Is based on actual water usage a...

Страница 10: ..._ is positioned in the display as follows Inst Date 3 01b Push and release the CHANGE DIGIT button until the value above the cursor is equal to the tens position of the desired Month setting 3 01c Co...

Страница 11: ...r is reached In this example set to Model 12AMQ 3 13 Push the NEXT button to the next parameter The display will show Save History NO This parameter if set to YES will save the current information you...

Страница 12: ...eter to Yes if a distiller or reverse osmosis system is plumbed to use soft water from the WaterMax 12 00a Push the CHANGE button to toggle parameter value from No to Yes In this example set to Distil...

Страница 13: ...required for setting the parameters of the CUSTOMER SETTINGS mode for OPERATING MODE 2 1 00 Push and hold the Customer Settings Next button to enter CUSTOMER SETTINGS mode The display will show Set T...

Страница 14: ...5 Pressure Drop Flow Rate Of 4 gpm 6 5 psi 8 5 psi 8 5 psi 8 5 psi 3 2 psi 6 psi 6 psi 7 psi 1 Salt Setting total length of reg Min gal 12 13 5 12 16 12 13 5 NA 12 24 NA NA NA 2 Salt Setting total le...

Страница 15: ...1 1 1 1 2 7 7 7 Brine rinse minutes 30 30 47 38 30 30 30 30 Backwash 2 minutes 3 3 3 3 2 2 2 2 Capacity salt lbs 28 730 6 2 lbs 28 730 6 2 lbs 44 840 9 6 lbs 28 730 8 5 lbs 28 730 6 2 lbs 28 730 6 2 l...

Страница 16: ...lbs 13 890 2 7 lbs 3 SALT SETTING Backwash 1 minutes 1 1 1 2 7 Brine rinse minutes 30 30 47 30 30 Backwash 2 minutes 3 3 3 2 2 Capacity salt lbs 28 730 6 2 lbs 28 730 6 2 lbs 44 840 9 6 lbs 28 730 6 2...

Страница 17: ...the wrong kind of See Fig 4 pg 19 salt can create a salt bridge This is a crust that forms an empty space between the water and salt To test use a blunt object like a broom handle Push the handle int...

Страница 18: ...ne stopped over sensor Run water Verify flashing light Read out lights do not glow Electric cord is unplugged Plug in transformer See Fig 1 pg 3 No electric power at outlet Check power source Make sur...

Страница 19: ...g in proper Defective magnet disk Replace magnet disk See Fig 8 pg 25 sequence Defective controller Replace controller See Fig 3 pg 18 Salty water Plugged injector Clean injector screen nozzle and thr...

Страница 20: ...0 Media Cabinet Cover 1 3 CO700 2 Pc Overflow 1 4 90837 Bypass Nut Gasket 2 5 90251 Bypass Nut 2 6 90254 Copper Adapter 2 90256 Cpvc Adapter Optional 2 7 90801 Support Panel Screws 4 8 93245 12v Trans...

Страница 21: ...PTION QU 1 90240 Brine Cabinet 1 2 90270 Support Panel 1 3 90289 Brine Cabinet Cover 1 4 90832 Cabinet Cover Clip 4 5 90626 Brine Well Safety Shutoff Assembly 1 6 90101 Grid Plate 1 93811 26 5 Air Che...

Страница 22: ...nd Cap Assembly 1 5 90240MT Media Tank Cabinet 1 6 90237 Support Panel 1 7 90812 Test Port Tube 1 8 93870 End Cap Screw 4 9 93809 End Cap Screw 2 10 93835 Spacer Tube 2 11 93808 End Cap O ring 2 12 93...

Страница 23: ...T DESCRIPTION QU 1 93223 Injector Throat 1 2 93220 Bottom Injector Seal thick 1 3 93221 Injector Nozzle 1 4 93232 Top Injector Seal thin 1 5 93222 Injector Cap 1 6 90807 Injector Screw 4 7 93810 Injec...

Страница 24: ...l hole flush on both sides is the one that creates the injection stream that enters the Throat It is very important that this hole is clear of debris round and undamaged If this hole becomes clogged d...

Страница 25: ...nsor Cap 1 22 90809 Sensor Cap Screw 1 23 93229 Flow Director 1 24 93838 I O Adapter O ring 2 90615 Bypass Assembly contains all items above PART DESCRIPTION QU 1 90246 Bypass Housing 1 2 90262 Bypass...

Страница 26: ...ither service or bypass it is only necessary to turn the Handle 90221 until the Piston 90616 stops Additional pressure torque will not improve the seal As a matter of fact once the Piston reaches the...

Страница 27: ...93514 AJG Brine Valve Housing Ass bly 1 9 90828 Drive End Cap O ring small 1 10 93238 Drive Gear 1 11 90818 Brine Valve Housing Screw 2 12 90809 Cam Cover Screw 2 13 93808 Drive End Cap O ring large 1...

Страница 28: ...ainless steel threaded stud should be pointing toward the Valve Body 93217 Piston Slide Cam This is the heart of the drive system There is a threaded stainless steel shaft that runs through the main d...

Страница 29: ...JG Housing Cap Assembly 1 3 90521 Piston Assembly 1 4 93805 Housing O ring 1 5 90843 5 gpm Flow Control 1 6 90807 Screw 2 7 93803 Brine Valve Housing O ring 1 8 200199 3 8 Locking Ring 1 9 93254 Brin...

Страница 30: ...n insert the new Quad ring and lock the retainer onto the housing by pushing in and turning counterclockwise to secure the Quad ring Replace the piston assembly and attach the brine valve assembly to...

Страница 31: ...are kept clean and free of debris Also both O rings should be in the proper locations one under the flange and one in the groove Do not overtighten the Fill Plug when assembling When the flange comes...

Страница 32: ...flow rate at varying pressures Care should be taken when replacing FCB s to insure that the correct rate is being used for a particular model Refer to Engineering Specifications pg 12 The flow contro...

Страница 33: ...2 H7041 Guide and Lock Set 1 3 H7039 Float Grommet 2 4 H7040 Bell Float 1 5 H7042 Float Washer 1 6 H7038 01 Float Rod 1 7 90102 3 5 X 26 5 Brine Well 1 8 C0700 2 Pc Overflow Fitting 1 9 93848 3 8 Bri...

Страница 34: ...moved from the elbow body Parts must be re assembled exactly as shown to function properly When connecting the 3 8 polytube it is first necessary to assemble the nut gripper and retainer sleeve on the...

Страница 35: ...salt used per regeneration DEPTH SALT inches lbs 6 74 7 1 5 8 2 2 9 3 0 10 3 7 11 4 4 12 5 2 13 5 9 14 6 6 15 7 4 16 8 1 17 8 8 18 9 6 19 10 3 20 11 0 21 11 8 22 12 5 23 13 3 24 14 4 PLEASE STUDY THE...

Страница 36: ...f any defective part or parts Hague Quality Water International will not be liable for nor will it pay service call or labor charges incurred or expended with respect to this warranty In the event the...

Страница 37: ...10 Series Owner s Manual 35 NOTES...

Страница 38: ...NOTES...

Страница 39: ...10 Series Owner s Manual 37 NOTES...

Страница 40: ...e in contact with the treated water are NSF listed or FDA approved Made in USA Manufactured using one or more of the following patent numbers 5 089 140 5 300 230 DES 332 480 DES 331 097 5 116 419 5 15...

Отзывы: