10 Series Owner’s Manual
This parameter is used to calculate a compensated hardness automatically.
7.00a Push the SELECT and CHANGE buttons until the desired iron number is displayed.
Example: Iron ppm 002
8.00 Push the NEXT button to step to the next parameter. The display will show:
Mang. ppm ###
8.00a Push the SELECT and CHANGE buttons until the desired manganese number is displayed.
Example: Mang. ppm 000
9.00 Push the NEXT button to step to the next parameter. The display will show:
Comp. Hard. ###
This parameter is the calculated compensated hardness using the hardness, iron and manganese
settings. The formula is (4 x each ppm iron) + (4 x each ppm manganese) + hardness = compensated
hardness. This is not a parameter that can be set. The display should now read: Comp. Hard. 0048
10.00 Push the NEXT button to step to the next parameter. The display will show:
Capty. Gr. #####
This parameter is used to set the softening capacity of the appliance. (See WaterMax engineering
specifications or setting charts on pages 12, 13 and 14 for capacities based on salt usage.)
10.00a Push the SELECT and CHANGE buttons until the desired capacity number is displayed. In this
example, set to: Capty. Gr. 28730
11.00 Push the NEXT button to step to the next parameter. The display will show:
72-96HourRegen No
This parameter, if set to “Yes”, is used to force the appliance to regenerate every 96 hours if regularly
scheduled regenerations based on water usage do not occur in 96 hours or less intervals. This should
always be “yes” if iron is present in the water.
11.00a Push CHANGE button to toggle parameter value from “No” to “Yes”. In this example, set to:
96HourRegen Yes
12.00 Push the NEXT button to step to the next parameter. The display will show:
Distill/RO
Set this parameter to “Yes” if a distiller or reverse osmosis system is plumbed to use soft water from
the WaterMax.
12.00a Push the CHANGE button to toggle parameter value from “No” to “Yes”. In this example, set to:
Distill/RO Yes
13.00 Push the NEXT button to step to the next parameter. The display will show:
Backwash 1 ##.#
(See
WaterMax setting chart for 17 through 20.) The “##.#” is the time, in minutes to the nearest tenth, for
which the first backwash cycle can be set.
13.00a Push the SELECT and CHANGE buttons until the desired backwash time is displayed. In this
example, set to: Backwash 1 07.0
14.00 Push the NEXT button to step to the next parameter. The display will show:
Brine/Rinse ##.#
The “##.#” is the time, in minutes to the nearest tenth, for which the first brine and slow rinse cycles
can be set.
14.00a Push the SELECT and CHANGE buttons until the desired combined brine and slow rinse cycle time is
displayed. In this example, set to: Brine/Rinse 30.0
15.00 Push the NEXT button to step to the next parameter. The display will show:
Backwash 2 ##.#
The “##.#” is the time, in minutes to the nearest tenth, for which the second backwash can be set.
15.00a Push the SELECT and CHANGE buttons until the desired backwash time is displayed.
In this example, set to: Backwash 2 02.0
16.00 Push the NEXT button to step to the next parameter. The display will show:
Salt lbs. ##.#
This parameter sets the amount of salt to be used to achieve the capacity setting. Remember, in
OPERATING MODE 2, WaterMax only uses as much salt as is needed to maintain the capacity
setting.
16.00a Push the SELECT and CHANGE buttons until the desired salt setting is displayed.
In this example, set to: Salt lbs 06.2
17.00 Push the NEXT button to step to the next parameter. The display will show:
Turbine # ###
This parameter is used to adjust the water metering system on the WaterMax. For a WaterMax, this value
should always be 135. It is very important that this parameter is set correctly or your WaterMax will not