background image

 

10 Series Owner’s Manual 

 

 

15

 

TROUBLE-SHOOTING 

PROBLEM 

  CAUSE    ACTION 

  

 
No soft water after  

 

No salt in brine tank. 

 

 

Add salt. 

regeneration. 

   

 

 

 

 

Sediment in brine tank has  

 

Remove the brine line and flush 

 

 

 

 

plugged the brine line and/or 

 

clean.  Clean air check.  Clean 

 

 

 

 

air check.  (See Fig. 12, pg. 31.)  

brine tank. 

 

 

 

 

 

 

Refill flow control is plugged.   

Remove brine piston housing and  

 

 

 

 

(See Fig. 9, pg. 27.) 

 

 

clear debris from the flow control. 

 
 

 

 

 

Drain line is pinched, frozen or   

Straighten, thaw or unclog the drain 

 

 

 

 

restricted.  (See Fig. 1, pg. 3.)   

line. 

 
 

 

 

 

Clogged injector assembly. 

 

Remove injector cap and clean 

 

 

 

 

(See Fig. 6, pg. 21) 

 

 

nozzle and throat with a wooden  

         toothpick. 

 

Replace 

throat 

if 

 

 

 

 

 

 

 

 

 

removed. 

 
 

 

 

 

Salt bridge has formed.   

 

High humidity or the wrong kind of 

 

 

 

 

(See Fig. 4, pg. 19) 

 

 

salt can create a salt bridge.  This is 

         a 

crust 

that 

forms 

an 

empty 

space 

 

 

 

 

 

 

 

 

 

 

between the water and salt.  To 

         test, 

use 

blunt 

object 

like 

broom 

         handle. 

 

Push 

the 

handle 

into 

the 

 

         salt 

to 

dislodge 

the 

salt 

bridge. 

 
No soft water.   

 

The plumbing bypass valve is in  

Place bypass valve in the service 

 

 

 

 

the bypass position. (See Fig. 7, pg. 23.) position. 

 
 

 

 

 

Appliance is plumbed in  

 

Check that appliance is plumbed 

 

 

 

 

backwards.  (See Fig. 1, pg. 3.)   

properly. 

 
    Extended 

power 

outage 

  Reset 

time. 

(See 

Customer 

Settings) 

 

Water hardness has increased 

Retest water and reset hardness.  (See 
Installation Record)  

 
Not metering water. 

Check light.  Light should flash with water 
usage.  If no light, see below. 

 
Blending dial is open. 

Make sure blending dial is closed. 

 

Light does not blink 

 

The bypass valve is in the  

 

Place bypass in the service position. 

when water is flowing.   

Bypass position.  (See Fig. 7, pg. 23.) 
 

Содержание Watermax 10 Series

Страница 1: ...10 Series Owner s Manual...

Страница 2: ...LUG ASSEMBLY 29 PARTS WATERMAX DRAIN END CAP ASSEMBLY 30 PARTS WATERMAX SAFETY SHUTOFF ASSEMBLY 31 PARTS BRINE VALVE ELBOW INSTALLATION INSTRUCTIONS 32 PARTS BRINE CABINET DATA 33 25 YEAR LIMITED RESI...

Страница 3: ...mix 2 Allow the appliance to regenerate at a time when the water is not being used If you have more than one appliance allow two hours between each regeneration 3 Protect your WaterMax including the d...

Страница 4: ...on ts 1 Do not install if the above items are not satisfactory 2 Do not install if incoming or outlet piping water temperature exceeds 120 F 3 Do not allow soldering torch heat to be transferred to va...

Страница 5: ...aste water In placing the 10 Series consider the following Install the 10 Series ahead of the water heater to prevent build up of hard water deposits in the water heater This placement will maintain t...

Страница 6: ...loor drain laundry tub or other suitable waste receptor Maintain a minimum of 2 50 mm air gap between the drain line and the flood level rim of the waste receptor to prevent back siphoning 5 Place the...

Страница 7: ...n Test the water at the test port to verify soft water 15 Place covers on both cabinets When using potassium chloride as an alternative to sodium chloride increase the hardness setting by 12 Note we d...

Страница 8: ...to accomplish various functions D CHANGE DIGIT FUNCTION Used to change values of parameters that can be set Used in conjunction with SELECT DIGIT button Used simultaneously with CHANGE DIGIT button t...

Страница 9: ...MER MODE Will regenerate based on frequency Example every 2 days or as specified up to 12 days Time of regeneration can be set MODE 2 PATENTED SAVEMATIC DEMAND DELAYED Is based on actual water usage a...

Страница 10: ..._ is positioned in the display as follows Inst Date 3 01b Push and release the CHANGE DIGIT button until the value above the cursor is equal to the tens position of the desired Month setting 3 01c Co...

Страница 11: ...r is reached In this example set to Model 12AMQ 3 13 Push the NEXT button to the next parameter The display will show Save History NO This parameter if set to YES will save the current information you...

Страница 12: ...eter to Yes if a distiller or reverse osmosis system is plumbed to use soft water from the WaterMax 12 00a Push the CHANGE button to toggle parameter value from No to Yes In this example set to Distil...

Страница 13: ...required for setting the parameters of the CUSTOMER SETTINGS mode for OPERATING MODE 2 1 00 Push and hold the Customer Settings Next button to enter CUSTOMER SETTINGS mode The display will show Set T...

Страница 14: ...5 Pressure Drop Flow Rate Of 4 gpm 6 5 psi 8 5 psi 8 5 psi 8 5 psi 3 2 psi 6 psi 6 psi 7 psi 1 Salt Setting total length of reg Min gal 12 13 5 12 16 12 13 5 NA 12 24 NA NA NA 2 Salt Setting total le...

Страница 15: ...1 1 1 1 2 7 7 7 Brine rinse minutes 30 30 47 38 30 30 30 30 Backwash 2 minutes 3 3 3 3 2 2 2 2 Capacity salt lbs 28 730 6 2 lbs 28 730 6 2 lbs 44 840 9 6 lbs 28 730 8 5 lbs 28 730 6 2 lbs 28 730 6 2 l...

Страница 16: ...lbs 13 890 2 7 lbs 3 SALT SETTING Backwash 1 minutes 1 1 1 2 7 Brine rinse minutes 30 30 47 30 30 Backwash 2 minutes 3 3 3 2 2 Capacity salt lbs 28 730 6 2 lbs 28 730 6 2 lbs 44 840 9 6 lbs 28 730 6 2...

Страница 17: ...the wrong kind of See Fig 4 pg 19 salt can create a salt bridge This is a crust that forms an empty space between the water and salt To test use a blunt object like a broom handle Push the handle int...

Страница 18: ...ne stopped over sensor Run water Verify flashing light Read out lights do not glow Electric cord is unplugged Plug in transformer See Fig 1 pg 3 No electric power at outlet Check power source Make sur...

Страница 19: ...g in proper Defective magnet disk Replace magnet disk See Fig 8 pg 25 sequence Defective controller Replace controller See Fig 3 pg 18 Salty water Plugged injector Clean injector screen nozzle and thr...

Страница 20: ...0 Media Cabinet Cover 1 3 CO700 2 Pc Overflow 1 4 90837 Bypass Nut Gasket 2 5 90251 Bypass Nut 2 6 90254 Copper Adapter 2 90256 Cpvc Adapter Optional 2 7 90801 Support Panel Screws 4 8 93245 12v Trans...

Страница 21: ...PTION QU 1 90240 Brine Cabinet 1 2 90270 Support Panel 1 3 90289 Brine Cabinet Cover 1 4 90832 Cabinet Cover Clip 4 5 90626 Brine Well Safety Shutoff Assembly 1 6 90101 Grid Plate 1 93811 26 5 Air Che...

Страница 22: ...nd Cap Assembly 1 5 90240MT Media Tank Cabinet 1 6 90237 Support Panel 1 7 90812 Test Port Tube 1 8 93870 End Cap Screw 4 9 93809 End Cap Screw 2 10 93835 Spacer Tube 2 11 93808 End Cap O ring 2 12 93...

Страница 23: ...T DESCRIPTION QU 1 93223 Injector Throat 1 2 93220 Bottom Injector Seal thick 1 3 93221 Injector Nozzle 1 4 93232 Top Injector Seal thin 1 5 93222 Injector Cap 1 6 90807 Injector Screw 4 7 93810 Injec...

Страница 24: ...l hole flush on both sides is the one that creates the injection stream that enters the Throat It is very important that this hole is clear of debris round and undamaged If this hole becomes clogged d...

Страница 25: ...nsor Cap 1 22 90809 Sensor Cap Screw 1 23 93229 Flow Director 1 24 93838 I O Adapter O ring 2 90615 Bypass Assembly contains all items above PART DESCRIPTION QU 1 90246 Bypass Housing 1 2 90262 Bypass...

Страница 26: ...ither service or bypass it is only necessary to turn the Handle 90221 until the Piston 90616 stops Additional pressure torque will not improve the seal As a matter of fact once the Piston reaches the...

Страница 27: ...93514 AJG Brine Valve Housing Ass bly 1 9 90828 Drive End Cap O ring small 1 10 93238 Drive Gear 1 11 90818 Brine Valve Housing Screw 2 12 90809 Cam Cover Screw 2 13 93808 Drive End Cap O ring large 1...

Страница 28: ...ainless steel threaded stud should be pointing toward the Valve Body 93217 Piston Slide Cam This is the heart of the drive system There is a threaded stainless steel shaft that runs through the main d...

Страница 29: ...JG Housing Cap Assembly 1 3 90521 Piston Assembly 1 4 93805 Housing O ring 1 5 90843 5 gpm Flow Control 1 6 90807 Screw 2 7 93803 Brine Valve Housing O ring 1 8 200199 3 8 Locking Ring 1 9 93254 Brin...

Страница 30: ...n insert the new Quad ring and lock the retainer onto the housing by pushing in and turning counterclockwise to secure the Quad ring Replace the piston assembly and attach the brine valve assembly to...

Страница 31: ...are kept clean and free of debris Also both O rings should be in the proper locations one under the flange and one in the groove Do not overtighten the Fill Plug when assembling When the flange comes...

Страница 32: ...flow rate at varying pressures Care should be taken when replacing FCB s to insure that the correct rate is being used for a particular model Refer to Engineering Specifications pg 12 The flow contro...

Страница 33: ...2 H7041 Guide and Lock Set 1 3 H7039 Float Grommet 2 4 H7040 Bell Float 1 5 H7042 Float Washer 1 6 H7038 01 Float Rod 1 7 90102 3 5 X 26 5 Brine Well 1 8 C0700 2 Pc Overflow Fitting 1 9 93848 3 8 Bri...

Страница 34: ...moved from the elbow body Parts must be re assembled exactly as shown to function properly When connecting the 3 8 polytube it is first necessary to assemble the nut gripper and retainer sleeve on the...

Страница 35: ...salt used per regeneration DEPTH SALT inches lbs 6 74 7 1 5 8 2 2 9 3 0 10 3 7 11 4 4 12 5 2 13 5 9 14 6 6 15 7 4 16 8 1 17 8 8 18 9 6 19 10 3 20 11 0 21 11 8 22 12 5 23 13 3 24 14 4 PLEASE STUDY THE...

Страница 36: ...f any defective part or parts Hague Quality Water International will not be liable for nor will it pay service call or labor charges incurred or expended with respect to this warranty In the event the...

Страница 37: ...10 Series Owner s Manual 35 NOTES...

Страница 38: ...NOTES...

Страница 39: ...10 Series Owner s Manual 37 NOTES...

Страница 40: ...e in contact with the treated water are NSF listed or FDA approved Made in USA Manufactured using one or more of the following patent numbers 5 089 140 5 300 230 DES 332 480 DES 331 097 5 116 419 5 15...

Отзывы: