Push the SERVICE SETTINGS button to enter SERVICE SETTINGS mode.  The display will show:  

Set 

language???

 

 
This parameter is used to set the language that is displayed in the CUSTOMER SETTINGS mode:  ENG – 
English, FRA – French, ESP – Spanish, DEU – German, ITA – Italian. 
 

 

1.00  Push the CHANGE DIGIT button until the correct language is displayed.  In this example, set to:  Set 

Language ENG. 

2.00  Push the NEXT button to step to the next parameter.  The display will show:  

Units ENG 

2.00a  Push the CHANGE DIGIT button to toggle English/metric units of measure.   

For this example, set to:  Units ENG. 

3.00  Push the NEXT button to step to the next parameter.  The display will show:  

History  NO

   This 

parameter is used to enter the History file.  The History file is used as a record of water readings for future 
reference.  (3.00 – 3.14 is an electronic notepad only and does not affect the operation of the appliance.) 

3.00a  Push the CHANGE DIGIT button to toggle between Yes or No.  Setting to “Yes” will enter the History 

file and setting to “No” will bypass the History file.  In this example, set to:     History   Yes 

3.01  Push the NEXT button and the display will show 

Soft Ver 1.00.

  This is information only and cannot be 

reset.  Push the NEXT  button to step to the next parameter.  The display will show:  

Inst. Date ######   

This parameter is to be set to the installation date of the appliance.  There are six digits.  The first two are 
the month. The next two are the day and the final two are the year. This is the first entry in the History 
file.   

3.01a  Push and release the SELECT DIGIT button until the cursor ( _ ) is positioned in the display as follows:  

Inst. Date ###### 

3.01b  Push and release the CHANGE DIGIT button until the value above the cursor is equal to the tens position 

of the desired Month setting. 

3.01c  Continue using the SELECT and CHANGE buttons until the desired date is displayed.  Example:  April 

22, 2000 = 042200 

3.01 d  Push the SELECT and CHANGE buttons until the desired date is entered. 
3.02  Push the NEXT button to step to the next parameter.  The display will show:   

# People  ##  

 This 

parameter is used to record the number of people in the household and should match the “# People” setting 
in the CUSTOMER SETTINGS file. 

3.02a   Push the SELECT and CHANGE buttons until the desired number of people in the household is reached.  

In this example, set to:  # People  04 

3.03  Push the NEXT button to step to the next parameter.  The display will show:  

Hard.  Gr.  ### 

This parameter is used to record the tested Hardness of the water. 

3.03a  Push the SELECT and CHANGE buttons until the desired hardness number is reached.  In this example, 

use 40 gpg:  Hard.  Gr.  040 

3.04  Push the NEXT button to step to the next 

Parameter.  The display will show:  

Iron  ppm  ### 

This parameter is used to record the tested iron content of the water. 

3.04a   Push the the SELECT and CHANGE buttons until the desired iron number is reached.  In this example, set 

iron to 002  (this is 2 ppm). 

3.05  Push the NEXT button to step to the next Parameter.  The display will show:  

Mang.  ppm  ### 

This parameter is used to record the tested Manganese content of the water. 

3.05a   Push the SELECT and CHANGE buttons until the desired manganese number is reached.  In this example, 

set to:  Mang.  ppm  000 

3.06  Push the NEXT button to step to the next Parameter.  The display will show:  

Chlor.  ppm  ### 

This parameter is used to record the tested chlorine content of the water. 
 

Содержание Watermax 10 Series

Страница 1: ...10 Series Owner s Manual...

Страница 2: ...LUG ASSEMBLY 29 PARTS WATERMAX DRAIN END CAP ASSEMBLY 30 PARTS WATERMAX SAFETY SHUTOFF ASSEMBLY 31 PARTS BRINE VALVE ELBOW INSTALLATION INSTRUCTIONS 32 PARTS BRINE CABINET DATA 33 25 YEAR LIMITED RESI...

Страница 3: ...mix 2 Allow the appliance to regenerate at a time when the water is not being used If you have more than one appliance allow two hours between each regeneration 3 Protect your WaterMax including the d...

Страница 4: ...on ts 1 Do not install if the above items are not satisfactory 2 Do not install if incoming or outlet piping water temperature exceeds 120 F 3 Do not allow soldering torch heat to be transferred to va...

Страница 5: ...aste water In placing the 10 Series consider the following Install the 10 Series ahead of the water heater to prevent build up of hard water deposits in the water heater This placement will maintain t...

Страница 6: ...loor drain laundry tub or other suitable waste receptor Maintain a minimum of 2 50 mm air gap between the drain line and the flood level rim of the waste receptor to prevent back siphoning 5 Place the...

Страница 7: ...n Test the water at the test port to verify soft water 15 Place covers on both cabinets When using potassium chloride as an alternative to sodium chloride increase the hardness setting by 12 Note we d...

Страница 8: ...to accomplish various functions D CHANGE DIGIT FUNCTION Used to change values of parameters that can be set Used in conjunction with SELECT DIGIT button Used simultaneously with CHANGE DIGIT button t...

Страница 9: ...MER MODE Will regenerate based on frequency Example every 2 days or as specified up to 12 days Time of regeneration can be set MODE 2 PATENTED SAVEMATIC DEMAND DELAYED Is based on actual water usage a...

Страница 10: ..._ is positioned in the display as follows Inst Date 3 01b Push and release the CHANGE DIGIT button until the value above the cursor is equal to the tens position of the desired Month setting 3 01c Co...

Страница 11: ...r is reached In this example set to Model 12AMQ 3 13 Push the NEXT button to the next parameter The display will show Save History NO This parameter if set to YES will save the current information you...

Страница 12: ...eter to Yes if a distiller or reverse osmosis system is plumbed to use soft water from the WaterMax 12 00a Push the CHANGE button to toggle parameter value from No to Yes In this example set to Distil...

Страница 13: ...required for setting the parameters of the CUSTOMER SETTINGS mode for OPERATING MODE 2 1 00 Push and hold the Customer Settings Next button to enter CUSTOMER SETTINGS mode The display will show Set T...

Страница 14: ...5 Pressure Drop Flow Rate Of 4 gpm 6 5 psi 8 5 psi 8 5 psi 8 5 psi 3 2 psi 6 psi 6 psi 7 psi 1 Salt Setting total length of reg Min gal 12 13 5 12 16 12 13 5 NA 12 24 NA NA NA 2 Salt Setting total le...

Страница 15: ...1 1 1 1 2 7 7 7 Brine rinse minutes 30 30 47 38 30 30 30 30 Backwash 2 minutes 3 3 3 3 2 2 2 2 Capacity salt lbs 28 730 6 2 lbs 28 730 6 2 lbs 44 840 9 6 lbs 28 730 8 5 lbs 28 730 6 2 lbs 28 730 6 2 l...

Страница 16: ...lbs 13 890 2 7 lbs 3 SALT SETTING Backwash 1 minutes 1 1 1 2 7 Brine rinse minutes 30 30 47 30 30 Backwash 2 minutes 3 3 3 2 2 Capacity salt lbs 28 730 6 2 lbs 28 730 6 2 lbs 44 840 9 6 lbs 28 730 6 2...

Страница 17: ...the wrong kind of See Fig 4 pg 19 salt can create a salt bridge This is a crust that forms an empty space between the water and salt To test use a blunt object like a broom handle Push the handle int...

Страница 18: ...ne stopped over sensor Run water Verify flashing light Read out lights do not glow Electric cord is unplugged Plug in transformer See Fig 1 pg 3 No electric power at outlet Check power source Make sur...

Страница 19: ...g in proper Defective magnet disk Replace magnet disk See Fig 8 pg 25 sequence Defective controller Replace controller See Fig 3 pg 18 Salty water Plugged injector Clean injector screen nozzle and thr...

Страница 20: ...0 Media Cabinet Cover 1 3 CO700 2 Pc Overflow 1 4 90837 Bypass Nut Gasket 2 5 90251 Bypass Nut 2 6 90254 Copper Adapter 2 90256 Cpvc Adapter Optional 2 7 90801 Support Panel Screws 4 8 93245 12v Trans...

Страница 21: ...PTION QU 1 90240 Brine Cabinet 1 2 90270 Support Panel 1 3 90289 Brine Cabinet Cover 1 4 90832 Cabinet Cover Clip 4 5 90626 Brine Well Safety Shutoff Assembly 1 6 90101 Grid Plate 1 93811 26 5 Air Che...

Страница 22: ...nd Cap Assembly 1 5 90240MT Media Tank Cabinet 1 6 90237 Support Panel 1 7 90812 Test Port Tube 1 8 93870 End Cap Screw 4 9 93809 End Cap Screw 2 10 93835 Spacer Tube 2 11 93808 End Cap O ring 2 12 93...

Страница 23: ...T DESCRIPTION QU 1 93223 Injector Throat 1 2 93220 Bottom Injector Seal thick 1 3 93221 Injector Nozzle 1 4 93232 Top Injector Seal thin 1 5 93222 Injector Cap 1 6 90807 Injector Screw 4 7 93810 Injec...

Страница 24: ...l hole flush on both sides is the one that creates the injection stream that enters the Throat It is very important that this hole is clear of debris round and undamaged If this hole becomes clogged d...

Страница 25: ...nsor Cap 1 22 90809 Sensor Cap Screw 1 23 93229 Flow Director 1 24 93838 I O Adapter O ring 2 90615 Bypass Assembly contains all items above PART DESCRIPTION QU 1 90246 Bypass Housing 1 2 90262 Bypass...

Страница 26: ...ither service or bypass it is only necessary to turn the Handle 90221 until the Piston 90616 stops Additional pressure torque will not improve the seal As a matter of fact once the Piston reaches the...

Страница 27: ...93514 AJG Brine Valve Housing Ass bly 1 9 90828 Drive End Cap O ring small 1 10 93238 Drive Gear 1 11 90818 Brine Valve Housing Screw 2 12 90809 Cam Cover Screw 2 13 93808 Drive End Cap O ring large 1...

Страница 28: ...ainless steel threaded stud should be pointing toward the Valve Body 93217 Piston Slide Cam This is the heart of the drive system There is a threaded stainless steel shaft that runs through the main d...

Страница 29: ...JG Housing Cap Assembly 1 3 90521 Piston Assembly 1 4 93805 Housing O ring 1 5 90843 5 gpm Flow Control 1 6 90807 Screw 2 7 93803 Brine Valve Housing O ring 1 8 200199 3 8 Locking Ring 1 9 93254 Brin...

Страница 30: ...n insert the new Quad ring and lock the retainer onto the housing by pushing in and turning counterclockwise to secure the Quad ring Replace the piston assembly and attach the brine valve assembly to...

Страница 31: ...are kept clean and free of debris Also both O rings should be in the proper locations one under the flange and one in the groove Do not overtighten the Fill Plug when assembling When the flange comes...

Страница 32: ...flow rate at varying pressures Care should be taken when replacing FCB s to insure that the correct rate is being used for a particular model Refer to Engineering Specifications pg 12 The flow contro...

Страница 33: ...2 H7041 Guide and Lock Set 1 3 H7039 Float Grommet 2 4 H7040 Bell Float 1 5 H7042 Float Washer 1 6 H7038 01 Float Rod 1 7 90102 3 5 X 26 5 Brine Well 1 8 C0700 2 Pc Overflow Fitting 1 9 93848 3 8 Bri...

Страница 34: ...moved from the elbow body Parts must be re assembled exactly as shown to function properly When connecting the 3 8 polytube it is first necessary to assemble the nut gripper and retainer sleeve on the...

Страница 35: ...salt used per regeneration DEPTH SALT inches lbs 6 74 7 1 5 8 2 2 9 3 0 10 3 7 11 4 4 12 5 2 13 5 9 14 6 6 15 7 4 16 8 1 17 8 8 18 9 6 19 10 3 20 11 0 21 11 8 22 12 5 23 13 3 24 14 4 PLEASE STUDY THE...

Страница 36: ...f any defective part or parts Hague Quality Water International will not be liable for nor will it pay service call or labor charges incurred or expended with respect to this warranty In the event the...

Страница 37: ...10 Series Owner s Manual 35 NOTES...

Страница 38: ...NOTES...

Страница 39: ...10 Series Owner s Manual 37 NOTES...

Страница 40: ...e in contact with the treated water are NSF listed or FDA approved Made in USA Manufactured using one or more of the following patent numbers 5 089 140 5 300 230 DES 332 480 DES 331 097 5 116 419 5 15...

Отзывы: