10 Series Owner’s Manual
17
TROUBLE-SHOOTING
PROBLEM
CAUSE ACTION
Broken valve assembly. Motor
Repair drive end cap. (See Fig. 8, p. 25.)
running. Magnet disk not turning.
Excess water in brine tank.
Restricted, frozen or pinched
Remove restriction, thaw or
drain line. (See Fig. 1, pg. 3.)
straighten drain line.
Plugged brine line, brine line flow
Clean flow control, air check and
control or air check. (See Fig. 9, p. 27.) brine line. (See Fig. 12, p. 31.)
Plugged injector assembly.
Clean or replace injector assembly.
(See Fig. 6, pg. 21.)
Replace throat if removed.
Sticking brine refill valve.
Remove valve. Lubricate piston
(See Fig. 9, pg. 27.)
with silicone grease and
reassemble.
Not regenerating in proper
Defective magnet disk.
Replace magnet disk. (See Fig. 8, pg. 25)
sequence.
Defective controller.
Replace controller. (See Fig. 3, pg. 18.)
Salty water
Plugged injector
Clean injector screen, nozzle and throat
(See
Fig.
6,
pg.
21.)
Low water pressure
Maintain minimum pressure of 30 psi
(See Engin. Specs, pg. 12.)
Drain line or flow control restricted
Remove restriction.
Brine line restricted or crimped
Remove restriction, replace if crimped.
Excessive amount of water in
Verify correct water level relative to salt
Brine
cabinet
setting.
Check
brine
line
and
fittings
for
loose
connections
(See
Brine
Cabinet
Data,
page
33.)
Insufficient rinse time
Check mode setting chart (pg. 13-14) for
proper brine Rinse time. Adjust time if
necessary.
Intermittent pressure drop
Install check valve on the inlet water line to
from feed source.
the appliance.
(Check local plumbing codes first.)