10.2. Navigation Menu
The Menu on the display can be access with the Return/Menu button on the front face of the controller. It is structured in different
chapters and is easy to navigate through it with the navigation pad. To select a screen use the navigation arrows , then
press the ok key to validate the selected screen.
CONTROL
- This menu allows to change the operation mode as well as to test position orders and engine start signals. (See chapter 10.6)
LOG
- In this menu, the operator can see the list of past events, search an event by date, see the statistics of the ATSE and manage
faults and alarms. (See chapter 10.7)
STATISTICS
- In this menu, the operator can see number of cycles and several operating hours.
GENSET SCHEDULER
- The operator can set 4 different customized engine start programs and schedule them in a cyclic or non-cyclic
mode. (See chapter 10.8)
PARAMETERS
- In this menu all the configuration parameters of the ATSE can be set, as well as timers, communication, alarms, I/O
and display parameters. Passwords and specific functions can also be set in this menu. (See chapter 11.1)
SPECIFIC FUNCTIONS
- All functions that are specific for the controller are inside this menu. See all the options in chapter 11.1.8.
MAINTENANCE
- This menu is reserved for maintenance purposes (service team). (See service chapter 12)
ABOUT
- The main information of the controller is showed on this menu: product serial number, firmware, communication address and
the maintenance telephone to call for the service.
The Home screen (Main Menu) can always be accessed by long-pressing the button from any other screen.
10.3. Operating modes
The controller has 4 types of operation modes:
MANUAL (CTRL mode):
it allows the user to take the control of the commands sent by the controller and the automatic procedure is
totally disabled.
To enter manual mode, click the Manual operation button:
The LCD will prompt the user to enter the operator password. The Manual mode LED will light up and the manual operation buttons will
be enabled. Select to switch to source 1, to go to source 2 and to go to center off position (if existing).
NOTE: In manual mode, if a source is lost, the genset (if
any) will start but the controller will not force a transfer.
The purpose is to keep the supply of the control and
the communications.
AUTOMATIC:
in automatic mode the controller will take the control over the switching device according to the settings (operating
range, timers, etc).
To switch from manual mode to Automatic mode, make sure there are no external inhibitions to automatic mode (inputs, cover open,
etc..) and click the automatic operation button:
The LCD will prompt the user to enter the operator password. The automatic mode LED will light up.
The switch may transfer as soon as automatic mode
has been enabled.
MAIN MENU
CONTROL
LOG
STATISTICS
GENSET SCHEDULER
PARAMETERS
SPECIFIC FUNCTIONS
MAINTENANCE