Chapter XI Electrical System
Great Wall Baoding Internal Combustion Engine
Manufacturing Company Limited
479
Fig. 11-3-14 Removing and reinstalling the
generator assembly
and tighten them according to specified torque. See
Fig. 11-3-14.
Tightening torque for the fastening bolt of the
generator
Bolt specification
Tightening torque
M8
23 N • m± 3 N • m
M10
45 N • m± 3 N • m
(2) Connect the generator connecting wires.
Fig. 11-3-15 Installing the generator belt
Installing the generator belt
②
(1) Set the generator belt at position so as to make
sure that the belt wedge teeth fit well with the pulley
wedge slot. See Fig. 11-3-15.
(2) Turn the tension pulley with a tool till the
generator belt is loose enough and then fit the
accessory flat idle wheel into the belt. Make sure
there is no excessive tension or insufficient tension.
After the installation, check the generator belt to
make sure the belt wedge teeth fit well with the
pulley wedge slot.
Fig. 11-3-16 Installing the generator terminals and
harness plug
Installing the generator terminals and harness
plug
①
(1) Inserting the generator harness plug
Hold the generator harness plug and insert it into
the harness connector.
(2) Connecting the generator terminal
Install the generator harness onto the terminal, and
tighten the fastening nut according to specified
torque.
Tightening torques for the fastening bolt of the
terminal
23 N • m ± 3 N • m