MAINTENANCE MANUAL OF GW4D20/GW4D20B TURBOCHARGED DIESEL ENGINES
118
Great Wall Baoding Internal Combustion Engine
Manufacturing Company Limited
(6) Long idle speed time.
(7) Overhigh pressure or oil level in the crankcase or blockage of crankcase vent.
(8) Overhigh engine lower blow-by.
Improper diagnosis method for oil leakage:
Remove the connecting pipe between the gas compressor housing exhaust port and the engine air
intake port, and then start the engine and check whether there are oil drops injected from the gas
compressor housing exhaust port with air flow.