Chapter X Electronic Control EGR System
Great Wall Baoding Internal Combustion Engine
Manufacturing Company Limited
459
Fig. 10-2-2 Removing the harness plug of the
EGR valve
Fig. 10-2-3 Removing the EGR condenser
Fig. 10-2-4 Removing the EGR valve
Removal
Preparations:
Remove the earthing cable of storage battery.
Removing the harness plug of the EGR valve
①
(1) Loosen the plug connecting the harness connector
and the EGR valve.
(2) Hold the plug and pull out the harness plug
connected with the EGR valve. See Fig. 10-2-2.
Caution:
Pull the plug connector instead of the
harness (the wire) when separating the circuit
connector.
Removing the EGR condenser component
②
(1) Remove 2 hexagon flange face bolts (M8 x16) from
the air outlet pipe of the EGR condenser. See Fig.
1-2-3.
(2) Remove 2 hexagon flange bolts (M8 x20) from the
intake pipe of the EGR condenser. See Fig. 1-2-3.
(3) Loosen the single-ear stepless clip fastening the
water inlet pipe and the water outlet pipe of the EGR
condenser. See Fig. 10-2-3.
(4) Remove 1 hexagon flange face bolt (M10x16)
fastening the EGR condenser bracket and the cylinder
head.
(5) Take off the EGR condenser from the cylinder head.
Removing the EGR valve assembly
③
(1) Remove 2 hexagon flange face nuts fastening the
EGR valve. See Fig. 10-2-4.
(2) Remove 2 hexagon flange face bolts (M8x20)
fastening the EGR valve and the EGR condenser intake
pipe, and the condenser intake pipe gasket. See Fig.
10-2-4.
(3) Take off the EGR valve assembly and the air outlet
gasket.
(4) Check the packing, and replace it if damaged or
deformed.
EGR valve