CE7000-UM-251-9370 20
9 TROUBLESHOOTING
Error
code
Error Display
Verification item
Cause
Solution
E03011
Confirm setting on the
application software.
An invalid byte was
received after ESC
code.
Configure your software
application menu to
permit Graphtec plotter
control. Re-specify the
software application’s
interface conditions.
Set the correct model
name if it was incorrect.
E03012
Invalid byte was
received within device
control command.
E03013
A parameter outside
of the permissible
range was specified
in the I/O related
command.
E03014
Too many parameters
in the I/O related
command.
E03015
Framing error, parity
error, or overrun error
has occurred.
Set the RS-232C
transmission condition.
E03016
Interface buffer
memory has
overflowed.