CE7000-UM-251-9370 7-39
7 DISASSEMBLY AND REASSEMBLY
How to detach the vacuum fan 2
(1) Detach the front guide (Refer to subsection 7.1.5.).
(2) Disconnect the cable of vacuum fan from the fan relay connector.
Fan relay cable connector
(3) Remove the M3L6 binding head screw holding the fan cover on the bottom of plotter, and then detach it.
M3L6 binding head screw
Fan cover
(4)
Remove the two M3L35 binding head screws holding the vacuum fan as shown in the figure below.
M3L35 binding head screw
Fan
(5) Detach the vacuum fan 2.
How to reinstall the fan 2
(1) Reattach in the reverse order in which it was detached.