CE7000-UM-251-9370 7-48
7 DISASSEMBLY AND REASSEMBLY
How to reinstall the Y Flexible cable
(1)
Fold the Y relay board side of Y flexible cable at same position with the removed Y flexible cable.
(2) Move the pen block to the left end.
(3)
Fit the Y-flexible cable into the Y-rail as shown below. Make a 10 mm slack from the left end of the Y
relay board (Y flexible cable bracket).
CE7000-40/60
CE7000-130/130AP/160
Y relay board
Y flexible cable bracket
Y flexible cable
Y flexible cable
10 mm
10 mm
(4)
Secure the Y-flexible cable onto the flexible cable guide of the Y-rail using double-sided adhesive tape.
(5) Reattach the other parts in the reverse order in which they were detached.
(6)
Confirm the wiring for Y flexible cable (Refer to subsection 7.4.).