SELF-TESTING
A general test of the instrument is carried out every time it is switched on, and the validity
of the data stored in the memory is checked. If this is found to be reliable, while the
function is being performed the following wording will appear on the display for a few
seconds:
t E S t
®
X
n o E r r o r
®
X
ABSOLUTE/INCREMENTAL COUNT
The LED of each Axis always signals the following:
•
AXIS LED ON
= AXIS IN ABSOLUTE COUNT (ABS) MODE
•
AXIS LED OFF
= AXIS IN INCREMENTAL COUNT (INC) MODE
•
AXIS LED WILL FLASH
= FUNCTION BEING PERFORMED
It is possible to switch either a single Axis or all the Axes from one counting mode to the
other as follows :
X
and/or
key
and/or
and/or
1 2 3. 4 5
®
Y
and/or
The LEDs of the activated Axes will flash
Z
press
1 2 3. 4 5
˜
X
The LED will light up (or extinguishes) and signal that the Axis is in ABS (or INC) mode.
The counting system is managed by the instrument, which has a dual internal counter
(ABS/INC) for each Axis. The information relating to the movement of the Axis updates
both counters at the same time. The information entered by the operator, on the other
hand, only affects the counter of the selected counting system. It goes without saying that
if the ABS counter is reset at a given point of the travel (ORIGIN) and the
INCREMENTAL counting mode is used (this is handier and more versatile to use), the
operator can then carry out all the resetting, pre-selections, functions and so on required
by the machining process, since he can return to the ABS count at any time to find out the
“absolute”
positions of the Carriages at that time and thus find the ORIGINS which had
been set.
Содержание VISION 700
Страница 69: ...10 06 2008 M042 E GQ 69 72 SPECIAL FUNCTIONS REQUIRED BY CUSTOMER...
Страница 70: ...10 06 2008 M042 E GQ 70 72...
Страница 71: ...10 06 2008 M042 E GQ 71 72 NOTES...
Страница 72: ...10 06 2008 M042 E GQ 72 72...