10/06/2008
M042.E
GQ
•
14
¥
72
INVERSION OF COUNTING DIRECTION
Switch on the instrument and wait for the end of the self-test cycle.
The displays remain on and show the zero search (rEF). Press
CLR
to enable the Axes for
counting. Move the Carriages by hand and decide which Axes need to be reversed (the
direction in which they advance depends on the mode of application of the rulers, and is
therefore random).
EXAMPLE
X AXIS =
TO BE REVERSED
Y AXIS =
CORRECT
Z AXIS =
TO BE REVERSED
PROGRAMMING THE AXES :
Key
98722
1
d i r -
®
X
The LED of the X Axis will then start to flash. The position of the dash (-) is purely
indicative.
press
(because it has to be reversed)
1
-
d i r
®
X
press
the selection is confirmed
and the X axis has been
reversed.
1
-
d i r
X
Once the operation has been completed, the instrument automatically goes on to consider
the next Axis (the LED of the Y Axis will start to flash).
Since, based on the example, this does not have to be reversed :
press
2
d i r -
Y
while for the Z Axis, which has
to be reversed:
3
d i r -
®
Z
press
(because it has to be reversed)
3
-
d i r
®
Z
press
X X X. X X
Z
On pressing EXE to confirm the last entry, the programming mode will be exited (all the
displays indicate dimensions). In the event of a wrong setting, press the CLR key and start
from the beginning again.