98
Troubleshooting
Model: WOG-MP-VH
7.01
Temperature Control System - continued
Problem
Probable Cause
Corrective Action
FRYER WILL NOT HEAT:
•
Power Light is
ON
•
Selector Switch is in
[COOK]
position
•
Continuous tone alarm sounding
•
“
MISSING FILTER”
message
(Computer) or Light
ON
(Mnaual)
A. Baffle Filter missing
Check, install Baffle Filter
B. Baffle Filter misaligned
Check, reinstall, or properly align
Baffle Filter
C. Charcoal Filter missing or mis-
aligned
Check, reinstall, or properly align
Charcoal Filter
FRYER WILL NOT HEAT:
•
Power Light is
ON
•
Selector Switch is in
[COOK]
posi-
tion
•
Heat Light is
OFF
•
Beeping tone alarm sounding
(Manual)
•
“CLEAN THE EAC”
message
(Computer)
•
CHECK/WASH
lights
ON
A. EAC Cell is excessively dirty
Clean the EAC Cell
B. EAC Cell has bent fins, or shorted
Repair EAC Cell
C. EAC Cell has too many broken ioniz-
er wires
Replace ionizer wires on Cell
D. Poor connection with Contact
Board; dirty or damaged
Clean contacts, or replace board
E. EAC Power Supply is faulty
Replace Power Supply
F. EAC Shutdown Module is faulty
Replace Module
G. EAC Cell is missing
Install or reinstall EAC Cell
FRYER WILL NOT HEAT:
•
Power Light is
ON
•
Selector Switch is in
[COOK]
position
•
High Limit Light is
ON
A. Power surge
Cycle Power Switch
OFF
for approx 5
secs, return to
[ON]
B. Low oil level
Check level, add oil as needed
C. Contactor sticking
Check/replace Contactor
D. High Limit Safety Board is faulty
Check/replace High Limit Board
E. High Limit Sensor is faulty, or out of
position
Check, adjust, or replace sensor
E. Controller is faulty
Check/replace Controller
FRYER WILL NOT HEAT:
•
Power Light is
ON
•
Selector Switch is in
[COOK]
position
•
Heat Light is
OFF
•
Constant tone alarm sounding
(Manual)
•
“CLOGGED FILTER”
message
(Computer)
A. Charcoal Filter clogged
Replace Charcoal Filter
B. Vacuum Switch requires adjust-
ment, or is faulty
Adjust Switch, replace if needed
C. Vacuum lines clogged or kinked
Check tubing clean, or remove kinks
D. Fan running too slow
Check voltage
E. Fan clogged with grease film
Clean fan
Содержание WOG-MP-VH
Страница 3: ......
Страница 7: ...vi Model WOG MP VH Table Of Contents ...
Страница 13: ...2 Model WOG MP VH Introduction Inches mm 1 04 Specifications 1 04 1 Overall Dimensions WOG MP VH ...
Страница 15: ...4 Model WOG MP VH Introduction ...
Страница 23: ...12 Model WOG MP VH Overview 1 2 5 6 7 3 4 Hidden 3 01 Cooking Vat ...
Страница 25: ...Model WOG MP VH Overview 14 1 2 3 8 4 7 5 6 3 02 Control Panel Computer Controller 4 1 4 2 9 ...
Страница 27: ...16 Model WOG MP VH Overview 3 02 1 Control Panel Manual Controls 1 2 3 10 9 7 8 11 5 5 6 6 12 12 4 ...
Страница 29: ...18 Model WOG MP VH Overview Hidden 3 03 Lower Cabinet Inside 2 3 7 5 6 4 1 ...
Страница 31: ...20 Model WOG MP VH Overview 3 04 Filter Pan Assembly 3 4 1 2 5 6 ...
Страница 33: ...22 Model WOG MP VH Overview Not Shown 3 05 Ventless Hood 2 3 7 5 6 4 1 ...
Страница 39: ...28 Model WOG MP VH Overview ...
Страница 45: ...34 Model WOG MP VH Pre Operation ...
Страница 99: ...88 Fryer Operation Model WOG MP VH ...
Страница 107: ...96 Cleaning Model WOG MP VH ...
Страница 115: ...104 Parts List Model WOG MP VH Not shown 8 03 Front Lower Cabinet 2 1 3 4 5 6 7 8 9 10 ...
Страница 117: ...106 Parts List Model WOG MP VH Not shown 8 04 Rear Lower Cabinet 2 1 5 3 4 ...
Страница 119: ...108 Parts List Model WOG MP VH 8 05 Cooking Vat 1 5 3 4 2 3 Not shown ...
Страница 121: ...110 Parts List Model WOG MP VH 8 06 Filter Pan Assembly 1 6 3 5 2 4 7 8 9 10 11 ...
Страница 123: ...112 Parts List Model WOG MP VH 8 07 Ventless Hood Front 1 5 3 4 2 9 8 10 6 7 Not shown 11 ...
Страница 127: ...116 Parts List Model WOG MP VH ...
Страница 128: ......