4. Programming Interfaces
Giga-tronics 2400/2500 Microwave Synthesizer Series
128
Programming Manual, Part Number 34783, Rev A, July 2009
4.6.6 GT-12000 Native Commands: Pulse Modulation
Table 26 GT-12000 Native Commands: Pulse Modulation
Number
Name
Comments
50
PM n
Activates and selects the source of the Pulse Modulation
according to the following:
n = 0 Deactivate Pulse Modulation.
n = 1 Activate external positive true PM.
n = 2 Activate internal PM.
n = 3 Activate external negative true PM.
n = 4 Activate internal PM and select external rising edge
trigger.
n = 5 Activate internal PM and select external falling edge
trigger.
51
PR d
HZ|KZ|KHZ|MZ|MHZ|GZ
|GHZ
Sets the pulse modulation internal rate to d.
52
PW d S|MS|US
Sets the pulse modulation internal width to d. (Requires
Option 24)
53
PWV n
Selects the waveform generated by the internal pulse
modulation generator according to the following:
n = 0 Selects no waveform.
n = 1 Selects singlet waveform.
n = 2 Selects doublet waveform.
n = 3 Selects triplet waveform.
n = 4 Selects quadlet waveform.
54
PI d S|MS|US
Sets the interval between pulses when waveform is set to
doublet, triplet, or quadlet. (Requires Option 24)
55
PY d S|MS|US
Sets the delay of the internal pulse modulation generator
waveform.