Giga-tronics 2400/2500 Microwave Synthesizer Series
4. Programming Interfaces
Programming Manual, Part Number 34783, Rev A, July 2009
117
Table 17 Source Subsystem – Modulation SCPI Commands
Command Syntax
Description
[SOURce]:PULSe:MODE OFF | TRIGered |
CONTinuous | GATEd
Sets the internal pulse modulation mode (Not
available with Option 17 or 17A). The choices are:
•
OFF - Turns internal pulse modulation mode
off.
•
TRIGgered - Sets the instrument to produce a
single internally generated RF output pulse
when a valid trigger signal is received at the
PM TRIG IN connector.
•
CONTinuous - Sets the instrument to produce
an internally generated pulse modulated RF
output signal continuously.
•
GATEd - Sets the instrument to produce an
internally generated pulse modulated RF
output signal for the duration of the externally
provided gate signal at the PM TRIG IN
connector.
[SOURce]:PULSe:PERiod <pm_per>
Sets the period of the internal pulse modulation
generator to the value specified by <pm_per>.
(Not available with Option 17 or 17A). The default
units are in Hertz unless otherwise specified.
[SOURce]:PULSe:SYNCdelay <pm_sync>
Sets the delay of the pulse modulation sync signal.
The delay range of the Pulse Sync Output function
is 100 nSec. to 10 mSec. (Not available with Option
17 or 17A) The default units are in Hertz unless
otherwise specified.
[SOURce]:PULSe:WIDTh <pm_width> (S|MS|US)
Sets the internal pulse modulation width to the
value specified by <pm_width> (Not available with
Option 17 or 17A).
[SOURce]:PULSe:WIDTh?
Queries the internal pulse modulation width. The
return value is in seconds
.
(Not available with
Option 17 or 17A).
[SOURce]:PULSe:DELay:STEP d
(Sec|MSec|USec|NSec)
Sets the increment value for pulse delay
[SOURce]:PULSe:DELay:STEP?
Query the increment value for pulse delay
[SOURce]:PULSe:EXTernal:SYNCdelay d
(Sec|MSec|USec|NSec)
Sets the external PM sync out delay
[SOURce]:PULSe:EXTernal:SYNCdelay?
Queries the external PM sync out delay
Continued next page