4. Programming Interfaces
Giga-tronics 2400/2500 Microwave Synthesizer Series
84
Programming Manual, Part Number 34783, Rev A, July 2009
4.3.3.67
DLL Function; GT2400_SetFMIntWavefrm
GT2400_SetFMIntWavefrm
Purpose
Set the FM internal waveform.
Syntax
STATUS
GT2400_SetFMIntWavefrm
(
const
unsigned
long
instrumentHandle,
const
short
FMIntWaveform)
Parameter
Description
instrumentHandle
Input: The unique identification of the instrument
FMIntWaveform
Input: FM internal waveform
1 = SINE
2 = SQUARE
3 = TRIANGLE
4 = RAMP