Giga-tronics 2400/2500 Microwave Synthesizer Series
4. Programming Interfaces
Programming Manual, Part Number 34783, Rev A, July 2009
147
4.7.8.6 Vernier Attenuation Commands
Table 39 Systron Donner Vernier Attenuation Commands
Vernier Attenuation Setting Commands
Output Level Relative to MAXIMUM Leveled Power Output
N2000
<not recommended>
+ 10.0 dBr
N2010
<not recommended>
+ 09.0 dBr
N2020
<not recommended>
+ 08.0 dBr
N2030
<not recommended>
+ 07.0 dBr
N2040
<not recommended>
+ 06.0 dBr
N2050
<not recommended>
+ 05.0 dBr
N2060
<not recommended>
+ 04.0 dBr
N2070
<not recommended>
+ 03.0 dBr
N2080
<not recommended>
+ 02.0 dBr
N2090
<not recommended>
+ 01.0 dBr
N2100
00.0 dBr *
N2110
- 01.0 dBr
N2120
- 02.0 dBr
N2130
- 03.0 dBr
N2140
- 04.0 dBr
N2150
- 05.0 dBr
N2160
- 06.0 dBr
N2170
- 07.0 dBr
N2180
- 08.0 dBr
N2190
- 09.0 dBr
N2200
- 10.0 dBr
N2210
- 11.0 dBr
N2220
- 12.0 dBr
N2230
- 13.0 dBr
N2240
- 14.0 dBr
N2250
- 15.0 dBr
Notes:
(1) * -- MAXIMUM Leveled Output Power at a given frequency.
(2) For each frequency, use command
O0N2100
(CW, attenuation set for 0 dBr) to verify MAXIMUM
leveled power accuracy prior to using attenuation programming commands. This should help determine
a realistic baseline for attenuation programming and scaling.