4. Programming Interfaces
Giga-tronics 2400/2500 Microwave Synthesizer Series
134
Programming Manual, Part Number 34783, Rev A, July 2009
4.7.3 HP 8673 Emulation Commands
Table 29 HP 8673 Emulation Commands
Number
Command
Description
1.
A0, A1, AO
Turn AM Off
2.
A2
Set AM to 30% range
3.
A3
Set AM to 100% range
4.
AP d (DB|DM)
Set CW output power level
5.
B0
Set filter switching mode to normal
6.
B1,BY
Set filter switching mode to bypass
7.
C1
Set Internal Automatic Leveling Control
8.
C2
Set external Automatic Leveling Control with negative diode
9.
CF d (GZ|MZ|KZ|HZ)
Set center frequency
10.
CFOA
Read center frequency
11.
CS
Clear status and extended status byte
12.
CW d (GZ|MZ|KZ|HZ)
Set CW frequency
13.
D0,D1
Turn FM Off
14.
D2
Set maximum FM deviation range to 30 KHZ
15.
D3
Set maximum FM deviation range to 100 KHZ
16.
D4
Set maximum FM deviation range to 300 KHZ
17.
D5
Set maximum FM deviation range to 1 MHZ
18.
D6
Set maximum FM deviation range to 3 MHZ
19.
D7
Set maximum FM deviation range to 10 MHZ
20.
DF
Set Delta Frequency
21.
DFOA
Read Delta Frequency
22.
DN
Decrement CW frequency by frequency increment step
23.
DO
Turn FM Off
24.
DW d (MS)
Set sweep dwell time in ms
25.
DWOA
Get sweep dwell time in ms
26.
F1 d (GZ|MZ|KZ|HZ)
Set frequency increment step
27.
FA d (GZ|MZ|KZ|HZ)
Set sweep start frequency
Continued next page