PITCH OR ROLL ANGLE EXCEEDED
If the machine shuts down because a forward/backward (pitch), or side (roll) tilt limit was exceeded, or no Rider
Detect sensors were depressed while the machine was moving at speed, the icon shown in the tablewill appear on
the InfoKey Controller. The machine is programmed to shut down in these situations because the rider is not in
control of the machine.
Follow instructions in the recommended action column of the table
Display icon
Description
Recommended action
The machine shuts down because
aforward/backward(pitch), or side
tilt limitwas exceeded, or no
Rider Detect sensorswere
depressed whilethe machine was
moving at speed.
Check the machine for damage. If there
is no damage, turn onpower by tapping
thePower/Standby buttonon the InfoKey
Controller.
SYSTEM FAULTS
If the machine detects a hardware fault, the icons shown in the tablewill appear on the InfoKey Controller.The
machine cannot be used until the fault is cleared.
To attempt clear system faults, follow the instructions in the RecommendedAction column of the table.
Display Icon
Description
Recommended Action
There is a fault in the Powerbase or
Batteries.
1. Power on machine
2. If the same icon appears,
confirm that both Li-ion
Batteries are installed
correctly.
3. If the same icon appears
remove and reseat both
Batteries (see
Removing
the Batteries
and
Reattaching the
Batteries
).
4. If the same icon appears, plug in
your machine and verifythat both Battery
ChargeIndicator lights are green. Plugin
and charge the machine overnight.