![GE Multilin 889 Скачать руководство пользователя страница 192](http://html.mh-extra.com/html/ge/multilin-889/multilin-889_instruction-manual_123014192.webp)
4–62
889 GENERATOR PROTECTION SYSTEM – INSTRUCTION MANUAL
DEVICE
CHAPTER 4: SETPOINTS
ALARM TYPE
Range: Off, Self-Reset, Latched
Default: Off
This setting specifies the alarm type. Self-Reset alarms track the state of the
corresponding input operand. Latched alarms can be reset using Reset pushbutton or
through Acknowledgement via graphical front panel.
The alarm type of each annunciator indicator may be configured as Off, Self-Reset, or
Latched. The default mode is Off. In this mode, the indicator is greyed out without any
text. In self-reset mode (Figure: Self-Reset Mode), the indicator’s inactive state is by
default in black background with dark grey color text. When the associated operand
becomes active (i.e. the assigned FlexOperand is triggered), the configured background
color and foreground text color appears. In latched mode (Figure: Latched), the
configured operand causes the background to flash when it becomes active. If the
alarm is then acknowledged or reset, the background stops flashing. If the operand
becomes inactive, the indicator returns to its default colors. The behavior of these modes
conforms to ISA-18.1-1979 (R2004) standard - A-4-5-6 (self-reset), and M-6 (latched).
Figure 4-13: Self-Reset Mode
Figure 4-14: Latched Mode
When any annunciator page is displayed with an alarm condition, the navigation keys
can be used to select an indicator. Once selected, the alarm condition can be
acknowledged by pressing the reset pushbutton or by pressing the enter key. A
confirmation message is displayed for acknowledging the alarm. Pressing the Reset or
Enter key again acknowledges the alarm and pressing the Escape button discards the
message. When the alarms are active under latched mode, a power loss retains the
previous state of the alarm as the alarm states are stored in non-volatile memory.
State: Normal
Visual: OFF
State: Abnormal
Visual: ON
O
p
er
an
d O
N
O
p
er
an
d
O
F
F
Reset PB to
Acknowledge
State: Normal
Visual: OFF
State: Abnormal
Visual: ON
Operand O N
O
p
er
an
d O
F
F
State: Alarm
Visual: Fast-Flash
Reset PB to
Acknowledge
AND
Operand O N
Reset PB to
Acknowledge
AND
Operand OFF
Reset PB to
Acknowledge
AND
Operand ON
Содержание Multilin 889
Страница 10: ...VIII 889 GENERATOR PROTECTION SYSTEM INSTRUCTION MANUAL ...
Страница 126: ...3 48 889 GENERATOR PROTECTION SYSTEM INSTRUCTION MANUAL SOFTWARE INTERFACE CHAPTER 3 INTERFACES ...
Страница 530: ...4 400 889 GENERATOR PROTECTION SYSTEM INSTRUCTION MANUAL TESTING CHAPTER 4 SETPOINTS ...
Страница 575: ...CHAPTER 8 MAINTENANCE ENVIRONMENTAL HEALTH REPORT 889 GENERATOR PROTECTION SYSTEM INSTRUCTION MANUAL 8 3 ...
Страница 580: ...A 4 889 GENERATOR PROTECTION SYSTEM INSTRUCTION MANUAL REVISION HISTORY CHAPTER A APPENDIX A ...