![Future Design MCTB 4.3 Скачать руководство пользователя страница 199](http://html1.mh-extra.com/html/future-design/mctb-4-3/mctb-4-3_user-manual_2352025199.webp)
MCTB
199
11.1.3.3 Accessing the MCTB through a VNC Viewer
The following examples are based on the use of the RealVNC viewer for PC/MAC. Once the default settings
have been entered, just enter the IP address and port number for the MCTB and
click the “Connect” button to
access the MCTB over the network.
Intranet Example:
If the IP address assigned is 192.168.3.5 and the configured VNC Address is 1, from the
PC’s VNC Viewer address field, enter '192.168.3.5:1’ to access the device (address 1 relates to port 5901,
address 2 to port 5902, etc., which is the port opened by the VNC server in order to allow communications with
the MCTB over the network).
Internet Example:
Internet connection usually requires a qualified network System Administrator. Typically, a
permanent IP address and specific port address are assigned to the MCTB; support on this action is beyond
the scope of this guide.
Consult your network system administrator for assistance in setting up an Internet
connection.
If the IP address of the LAN is 69.216.64.69 and the configured VNC Address is 1 (port 5901 has been opened
and assigned to this specific MCTB controller), from the remote PC (outside of the site Servers LAN), in the
VNC Viewer address field enter
‘69.216.64.69::5901’ to access the device (5901 relates to address 1, 5902 to
address 2, 5903 to address 3, etc., note the double colon).
NOTE:
The IP address shown on the communications screen of the MCTB is the local LAN address and
would not typically be used for an Internet connection.
Security Example:
If the VNC server password is enabled on the MCTB for either example above, upon
pressing the “Connect” button to make the connection, the VNC viewer will prompt for the proper password.
The connection will only be established once a valid password is entered.
Содержание MCTB 4.3
Страница 24: ...MCTB 24...
Страница 195: ...MCTB 195...
Страница 227: ...MCTB 227 A 5 SmartIO Monitor Module Specifications...
Страница 228: ...MCTB 228 A 6 Expansion IO Module Specifications...
Страница 229: ...MCTB 229 A 7 Power Supply Specifications DIN Rail Mount Power Supply Specifications...
Страница 230: ...MCTB 230...
Страница 231: ...MCTB 231 Open Frame Power Supply Specifications...
Страница 232: ...MCTB 232...
Страница 233: ...MCTB 233 A 8 Power On Delay Relay Specifications GE1A C10HA110...
Страница 234: ...MCTB 234...