MCTB
190
It is recommended that this field be left blank for the majority of
users to insure all configuration files are stored in the base
“configs” directory. When loading a configuration for import,
only the files in the specified directory will be available for
selection. If a configuration file was stored to a location
specified by the Server field and the proper entry is not known,
the user will be unable to select the proper configuration file for
import.
User Name =
userName
Actual user name for login at FileWeb server (required).
Password =
userPassword
Actual password for login at FileWeb server (required).
NOTE:
Make sure proper permissions are set at the server for access/creation of directories and read/write
access. Also check root directory structure at the server to identify the actual root that was created for
the files since there can be additional layers created by the server field and displayed in the path (see
Appendix section A.2 FTP, FileWeb, DataWeb Requirements/Installation for additional information).
10.7.2 Importing an OEM Default Configuration
The “Reset default configuration” button loads a predefined configuration stored in memory on the MCTB. The
factory configuration is “blank” meaning it will reset all attached loop control boards and limit control to the FDC
factory defaults. All user and/or EOM configuration settings will be cleared which will require the user to
reconfigure the entire device for the intended application.
For OEM manufacturers, the MCTB provides a means of importing a default factory configuration. If an end
user happens to make configuration changes that affect operation, or to insure the system is configured properly
to OEM specifications while providing customer support, the OEM configuration can be stored in the MCTB and
w
ill be installed when the “Reset default configuration” button is pressed.
To import a factory default configuration, insert the USB memory device containing the desired configuration
file. Next to the “Home” icon is a hidden button. Tap the location repeatedly 10 times within a period of 4
seconds. A dialog will be shown prompting to copy a configuration as factory defaults. When “Yes” is selected,
the open file screen will be shown. Select the desired co
nfiguration file and press the “Open” button to import
the file as factory defaults.
NOTE:
Importing a factory defaults file does not affect the current configuration of the unit. This only imports
a configuration file as the factory defaults file.
Hidden Import Factory
Defaults Button
Содержание MCTB 4.3
Страница 24: ...MCTB 24...
Страница 195: ...MCTB 195...
Страница 227: ...MCTB 227 A 5 SmartIO Monitor Module Specifications...
Страница 228: ...MCTB 228 A 6 Expansion IO Module Specifications...
Страница 229: ...MCTB 229 A 7 Power Supply Specifications DIN Rail Mount Power Supply Specifications...
Страница 230: ...MCTB 230...
Страница 231: ...MCTB 231 Open Frame Power Supply Specifications...
Страница 232: ...MCTB 232...
Страница 233: ...MCTB 233 A 8 Power On Delay Relay Specifications GE1A C10HA110...
Страница 234: ...MCTB 234...