The MCTB controller includes the following features:
ACCESSIBILITY
•
Touch screen, “Smart Device” user interface (UI) with
30,000-hour
(4.3”) or 50,000 (7”) LED display
•
Built in configuration software; no external software or
PC required
•
Email, SMS, FTP, FileWeb, DataWeb, VNC and Web
functionality standard
•
Remote View/Control using PC, Tablet or Smartphone.
•
National time server connectivity with daylight savings.
COMMAND BAR ICONS
NAVIGATION, HELP & HOME
The Master Command Bar located on the top of the
display provides easy & intuitive 1-touch access from
anywhere in the system to Navigation, Help and
configured Home view.
Home brings th
e user back to the system “Home” view.
The Home icon can be configured for the following
standard views:
•
Loop view: includes PV & SP digital display, PV
min/max, PID % Output, Auto-Manual, event, profile
access and more.
•
Overview: all loops, profile and event status
•
Chart view: (trend up to the last 24 hours from system
RAM) supporting 4 trends with up to 6 values per trend
•
Alarm view or Alarm File
Help offers content sensitive text for every view / page
in one of 11 supported languages chosen by the user.
Navigation provides access to the configured menu
system, traditional drop down or icon.
SECURITY AND AUDIT TRAIL
•
Supports up to 30 users over four user groups with
access to 40+ functions restricted by user group.
•
Supports password aging and verification.
•
Operator Audit Trail provides history for all user activity
that includes date, time, user name and action; i.e.,
Loop SP change from 55.2 to 103.5.
PROFILE RAMP/SOAK
•
Up to three loops
•
Start: via touch screen or Event input
•
Profile Name: 16-character naming convention
•
Global Profile Configuration:
- Start from PV or static SP
- Guaranteed Soak & Ramp band
- Power Fail / Recovery: Continue from last SP value,
PV or static mode.
•
Profile Segments: (maximum of 64)
•
Guaranteed Soak & Ramp per step
•
Events: up to 9 events per step (3 events per loop)
•
Jump-To Step: configurable per step
•
Profile End Alarm
•
Configurable Profile End Logic:
- Current (Static) Control SP: set point and event
status prior to profile start is loaded at end of profile
- Final SP of profile with all events off
- Last step of profile SP and events are held
when profile stops
ALARMS
• Up to 19 alarms, 10 soft configurable to B42 & L41, up to
3 alarm outputs per B42 and L41 up to 2 alarm outputs.
• Loop* Alarm Types: Process High & Low, Deviation High
& Low, Deviation Band and Event Input.
* B42 configured as Monitor Input (no PID control)
configurable only with process and event input
alarms.
Alarm Mode:
Normal or Hold (on start-up Hold mode will not
activate if in alarm condition and arm once out of
alarm condition).
Silent Alarm, activation does not indicate alarm or
write to alarm log file.
Alarm outputs configurable as latching or non-
latching.
DATA ACQUISITION
• Data log PV, SP and PID percent output.
• File name: Free form 16 character appended by
time/date or the profile name if started with a profile.
• File Start/Stop: user on-demand, on system boot or
profile ramp-soak start/end.
• Data Log interval: configurable 1 seconds to 31 minutes.
• File Interval: configurable to set time in days (1 to 31) to
end and start a new file. This allows syncing files to
match product cycles as well as keeping file size
manageable.
• ID#1 and ID#2 fields allow user to enter specific
information such as a batch and/or lot information that is
associated with the data file.
• Operator
Comments/Events:
Unlimited
operator
comments/events linked to each file
• File Type: Data Log files are saved in .csv format.
• Digital Signatures: Automatic system as well as user
entered signatures.
• Historical Data Viewer: View data log fi les on the display.
Chart is auto-scaled on an X & Y axis for time and units.
• Meets the requirements for:
- CFR21 Part 11
- AMS2750E
EVENT INPUTS
• B42 / L41 each have 1 event input configurable for one
of the following functions.
- B42: Profile Run/Abort, Hold/Resume, Run/Hold,
Failure Transfer (Outputs), Alarm Input (indication
only) and Loop Status Input
- L41: Remote Reset, Panel Lock
MATH/LOGIC
• Up to 20 configurable math/logic equations.
- Math equations allow calculations to be performed on
any of the process values. Results are displayed on
the Overview screen and can be selected for
logging/trending.
- Logic equations can be assigned to event outputs
allowing the output to turn on/off based on user
defined conditions.
Содержание MCTB 4.3
Страница 24: ...MCTB 24...
Страница 195: ...MCTB 195...
Страница 227: ...MCTB 227 A 5 SmartIO Monitor Module Specifications...
Страница 228: ...MCTB 228 A 6 Expansion IO Module Specifications...
Страница 229: ...MCTB 229 A 7 Power Supply Specifications DIN Rail Mount Power Supply Specifications...
Страница 230: ...MCTB 230...
Страница 231: ...MCTB 231 Open Frame Power Supply Specifications...
Страница 232: ...MCTB 232...
Страница 233: ...MCTB 233 A 8 Power On Delay Relay Specifications GE1A C10HA110...
Страница 234: ...MCTB 234...