User Right
Menu Location
Description
Default Configuration
Device/Settings/Offline/System/
Configuration; Reset Default
Configuration button
function to clear system configuration and reset all to
blank (default) state for reconfiguring
Exit (run mode)
Device/Settings /Offline/System/Exit;
“Exit application. (automatic mode
startup).” button
prevents MCTB application from being stopped
Exit to Configurator
Device/Settings /Offline/System/Exit;
“Exit Application. (configuration mode
startup).” button
prevents MCTB application from being stopped and
access to the MCTB configurator application
Cascade
Device/Settings //Cascade
Set cascade settings when cascade control enabled.
Calibrate Inputs
Device/Settings /Offline/Calibrate
Provides user offset calibration or full calibration of all
MCTB inputs.
7.4 Setting Security Options
The security
“Options” tab provides the administrator the ability to set the global security options.
Security
is the global setting that turns the MCTB security system on or off. The security system must be
enabled for the audit trail to be enabled.
Audit
is a global setting that turns the audit trail on or off. When the audit trail is turned on, all user actions are
written to a daily log.
When enabled,
Verification
requires that the logged in user must log in again before the entry value will actually
be changed. This option is mutually exclusive with 2FA, i.e., only one can be enabled at a time.
Two-factor authentication (
2FA
) requires users to be added to the system with valid SMS numbers associated
to their personal devices. During log in, when 2FA is enabled, the system will send the user a verification code
that they must then enter to complete the log in process. See the following section regarding two-factor
authentication and its use.
IMPORTANT: In order for 2FA to function, the system must be connected to the internet and valid email server
settings must be entered (see section
). If the system does not have
internet access and/or email settings are not properly entered, the system will be unable to
send log in verification codes and users will not be able to log in to the system.
The
Password Aging Days
field is a global for all users. Password aging starts from the day the user is
entered into the system. The value can be set from 0 to 365 days. A value of zero disables password aging.
Содержание MCTB 4.3
Страница 24: ...MCTB 24...
Страница 195: ...MCTB 195...
Страница 227: ...MCTB 227 A 5 SmartIO Monitor Module Specifications...
Страница 228: ...MCTB 228 A 6 Expansion IO Module Specifications...
Страница 229: ...MCTB 229 A 7 Power Supply Specifications DIN Rail Mount Power Supply Specifications...
Страница 230: ...MCTB 230...
Страница 231: ...MCTB 231 Open Frame Power Supply Specifications...
Страница 232: ...MCTB 232...
Страница 233: ...MCTB 233 A 8 Power On Delay Relay Specifications GE1A C10HA110...
Страница 234: ...MCTB 234...