![Furuno FCV-38 Скачать руководство пользователя страница 139](http://html1.mh-extra.com/html/furuno/fcv-38/fcv-38_manual_2349641139.webp)
AP-1
APPENDIX 1 MENU TREE
[Advanced Settings] menu
Sounder
Color Erase (0~50%;
0%
)
White Edge (
Off
, 1~10)
Clutter
(
Std
, Linear)
TVG Level (0~9;
0
)
TVG Distance (100~3000ft;
300ft
)
STC
(0~10;
0
)
Bottom
Zone
Above (15~70%;
50%
)
Below (30~85%;
85%
)
Display A-Scope
(
Normal
, Peak)
Temp Graph (Narrow,
Normal
, Wide)
Temp Color (
Normal
, White, Red, Black)
Zoom Marker (Off,
On
)
Colors
(16,
64
)
Hue
(
Normal
, Hue1~Hue5, Custom)
Custom (Setting window appears.)
Background (White, Light Blue, Blue,
Dark Blue
, Black, Custom)
Custom (Setting window appears.)
Depth Scale (
Right
, Center)
Net Depth Mark (
Off
, On)
Net Depth Mark ID (Setting window appears.)
Mark Color (Setting window appears.)
Mark Width (1~4;
1
)
Net Sensor Temp Graph (Net ID0~Net ID15;
Net ID0
)
Transparency
(
Off
, 1~4)
ModeGain Display (
Off
, On)
Beam Direction Display (
Off
, Figure, Letter, Letter)
Data Position (
Upper Left
, Lower Left, Upper Right, Lower Right)
Fish Size
Auto Specific Area (
Off
, Auto Depth, Auto Area)
Measurement
Target Measurement Area (SIZE1, SIZE2, SIZE3)
Updating Cycle (
High
, Medium, Low)
Auto Measurement Range Time Direction (Entire Area, 1/2,
1/3
)
Updating Cycle (RT, 1s, 2s,
3s
)
Measurement Range (
Std
, Entire Range)
Measurement Threshold (2~8inch;
3inch
)
SIZE1
Graph
Display
(Horizontal,
Vertical
)
Graph Scale End (16inch, 24inch, 32inch,
39inch
, 47inch, 63inch, 79inch)
Distributed Scale Start (0~5%;
3%
)
Distributed Scale End (10~100%;
50%
)
Graph Peak (
1st
, 1st+2nd, 1st+2nd+3rd)
Emphasis
Type
(
Off
, Type1, Type2, Type3)
Emphasis Rate (Weak,
Medium
, Strong)
Offset
(-10.0~+30.0dB;
0.0dB
)
TScm
(-100~-50dB;
-66dB
)
SIZE2 (Same as SIZE1.)
SIZE3 (Same as SIZE1.)
Default settings in bold italic.