Setting for Defrost determination control
1. Switch to “Local setting mode” by pressing [MODE] button (SW107) for 3 seconds or more.
2. Confi rm (POWER / MODE) blinks 9 times, and press [ENTER] button (SW109).
POWER
ERROR
PUMP
DOWN
LOW NOISE
PEAK CUT
MODE
(L1)
(L2)
(L3)
(L4)
(L5)
(L6)
Blink
(9 times)
O
O
O
O
O
O
O
Sign “
O
”: Lights off ; “
O
”: Lights on ; () : Number of blinking.
3. Press [SELECT] button (SW108), and adjust LED lamp as shown below
(current setting is displayed, L5 or L6 is lights on).
PUMP
DOWN
LOW NOISE
PEAK CUT
(L1)
(L2)
(L3)
(L4)
(L5)
(L6)
Defrost determination
control
Blink
O
O
O
O
O
Sign “
O
”: Lights off ; “
O
”: Lights on.
4. Press [ENTER] button (SW109) (L5 or L6 is blinking).
PUMP
DOWN
LOW NOISE
PEAK CUT
(L1)
(L2)
(L3)
(L4)
(L5)
(L6)
Defrost determination
control
O
O
O
O
Blink
Blink
Sign “
O
”: Lights off ; “
O
”: Lights on.
5. Press [SELECT] button (SW108), and adjust LED lamp as shown in below fi gure.
PEAK CUT
(L4)
(L5)
(L6)
Defrost determination
control
Level 1
(Nornal)
O
O
Blink
OR
OR
Level 2
(Quicker)
O
Blink
O
Sign “
O
”: Lights off ; “
O
”: Lights on.
6. Press [ENTER] button (SW109) and fi x it.
PEAK CUT
(L4)
(L5)
(L6)
Defrost determination
control
Level 1
(Nornal)
O
O
O
OR
OR
Level 2
(Quicker)
O
O
O
Sign “
O
”: Lights off ; “
O
”: Lights on.
7. Return to “Operating status display (Normal operation)” by pressing [EXIT] button (SW112).
When pressed number is lost during operation, restart from the beginning of operation procedure after returning to “Operation status display
(normal operation)” by pressing the [EXIT] button (SW112) once.
Waterstage / Maintenance Manual / 2105 - EN