- 66 -
Heating Circuit Assignment
Line Nr
Programming line
70
Software version
Software version
The indication shows the current version of the user
interface.
▼ Time Program Functions (heating circuit 1 & 2, DHW, cooling)
Several control programs are available for the heating circuits and the production of DHW. They are initiated in
"Automatic" mode and control the change in temperature levels (and therefore the associated setpoints, reduced
and comfort) via the adjusted changeover times.
Enter changeover times
Changeover times can be adjusted in a combined way, i.e., identical times for several days or distinct times for
certain days. Preselecting groups of days (e.g., Mon...Fri and Sat...Sun) having the same changeover times makes
adjustment of the changeover program considerably shorter.
Standard Program
Line Nr
Programming line
516, 536, 576, 616
Default values (No /Yes)
All time programs can be reset to factory settings.
Each time program has its own command line for this
reset action.
In this case, individual settings will be lost !
Holidays
Line Nr
Programming line
HC1
HC2
642
652
Period start (Day / Month)
643
653
Period end (Day / Month)
648
658
Operating level
The holiday program enables changing the heating
circuits over to a selected operating level according to
the date (calendar).
Important !
The holiday program can be used only in the automatic
mode.
Changeover Points
Line Nr
Programming line
HC1
HC2
4/DHW
5
500
520
560
600
Preselection (Mon-Sun / Mon-Fri / Sat – Sun / Mon...Sun)
501
521
561
601
1st phase On
502
522
562
602
1st phase Off
503
523
563
603
2nd phase On
504
524
564
604
2nd phase Off
505
525
565
605
3rd phase On
506
526
566
606
3rd phase Off
Waterstage / Maintenance Manual / 2105 - EN