- 92 -
▼ Generator Diagnosis Functions
Various setpoints and actual values, relay switch status
data can be displayed for purposes of diagnosis.
Heat Pump
Line Nr
Programming line
8402
El imm heater fl ow 1
8403
El imm heater fl ow 2
8406
Condenser pump
These command lines are used to check the operating
mode of the components controlled by the heat pump relays.
The display "0" means that the associated components
are currently disconnected. The display "1" means that
the associated components are currently switched on.
Information
This information applies to relays defi ned as normally open
contacts. For normally closed contacts, the action is reversed.
Setpoints and Measured Values
Line Nr
Programming line
8410
Return temp HP
8412
Flow temp HP
8413
Compressor modulation
8414
Modulation electric fl ow
8425
Temp diff condenser
These lines allow the various setpoints and measured
values for the heat pump to be viewed.
Hour / Startup Counter
Line Nr
Programming line
8450
Hours run compressor 1
8454
Locking time HP
8455
Counter number of locks HP
8456
Hours run el fl ow
8457
Start counter el fl ow
Hours run compressor 1 :
This operating line shows the total number of hours run
of compressor 1 since it was fi rst commissioned.
Locking time HP
Displays the cumulative locking time since start-up by
the electrical services (via external locking signal).
Counter number of locks HP
Displays the cumulative locks since start-up by the
electrical services (via external locking signal).
Hours run el fl ow, Start counter el fl ow
These lines are used to view the hours of operation and
the number of startups of electric heater.
▼ Consumer Diagnosis Functions
Various setpoints and actual values, relay switch status
and timing status data can be displayed for purposes of
diagnosis.
Outdoor Temperatures
Line Nr
Programming line
8700
Outside temperature
8701
Outside temp min
8702
Outside temp max
8703
Outside temp attenuated
8704
Outside temp composite
The current, minimum, maximum, attenuated and
composite outdoor temperatures are displayed.
Heating Circuits
Line Nr
Programming line
8730 and
8760
Heating circuit pump, circuit 1
8731 and
8761
Mixer valve HC1 open
8732 and
8762
Mixer valve HC1 closed
8740 and
8770
Room temp
8743 and
8773
Flow temp
The display "Off " means that the associated components
are currently disconnected.
The display "On" means that the associated components
are currently switched on.
Cooling Circuit
Line Nr
Programming line
8756
Flow temperature cooling 1
8757
Flow temperature setpoint cooling 1
The actual values of the cooling mode are displayed.
The cooling mode room setpoint is displayed on
programming line 8741.
Waterstage / Maintenance Manual / 2105 - EN