- 85 -
Sensor Corrections
Line Nr
Programming line
6098
Not used
6100
Readjustm outside sensor
The outdoor temperature measuring value can be
corrected within a range of +/- 3 K.
Installation Frost Protection
Line Nr
Programming line
6120
Frost protection plant
According to the outdoor temperature, the heating
circuit pump and the condenser pump are switched on
although there is no demand for heat.
Outdoor
temperature
Pump
Diagram
Continuously ON
Set to ON for 10 min, approx. every
6 hours.
Continuously off
ON
Periodically ON
OFF
Miscellaneous
Line Nr
Programming line
6205
Reset to default parameters
6220
Software version
Reset to default parameters
All parameters can be reset to factory settings, except
when it comes to the following pages: Time and date,
User interface and all time programs, as well as the
operating hours and the various counters.
Software version
The software version represents the controller software
status at the time the unit is being produced. It is printed
on the back of the unit.
The fi rst two digits represent the software version,
and the third is the revision number (e.g. 01.0)