MB95630H Series
MN702-00009-1v0-E
FUJITSU SEMICONDUCTOR LIMITED
423
CHAPTER 21 MULTI-PULSE GENERATOR
21.5 Operations
■
16-bit Timer Timing
The 16-bit timer increases its value at timing according to the prescaler clock and counts up at
a rising edge.
Note:
Before the prescaler clock is changed, the Timer Counter should be disabled first by
setting the TMEN bit to "0".
Figure 21.5-29 16-bit Timer Count Timing
The counter can be cleared upon a reset, software clear (TCLR), a match with the compare
clear register, the Write Timing signal or the Position Detection signal. By a reset, the counter
is immediately cleared. By a match with the compare clear register, software clear (TCLR), the
Write Timing signal or the Position Detection signal, the counter is cleared in synchronization
with the count timing.
Figure 21.5-30 16-bit Timer Clear Timing
N
N+1
Counter value
Prescaler clock
N+2
N+3
N+4
CPU clock
N
N - 1
0x0000
Compare
register value
Compare match
Counter value
Prescaler clock
N
0x0001
0x0002
MCLK