170
16. Interface Setting
16-1. GPI and Tally Control
HVS-3800HS/S units have GPI IN / OUT interface capability to allow other devices to initiate
switcher operations and for output of switcher operational status / tallies to other devices. Use of
GPI IN/OUT pins can be freely assigned within GPI IN, GPI OUT and TALLY1-5 sub-menu
pages of the FUNCTION - GPI/TALLY menu.
NOTE
In HVS-16/24OUA, you can quickly access the FUNCTION - GPI/TALLY menu above
by rapidly pressing the GPI button in the EFFECT/STILL section twice.
16-1-1. GPI IN Free Assignments
In the FUNCTION - GPI/TALLY submenu, set the SELECT to 2.
Press F1 or the DOWN button to display GPI IN submenu page.
For GPI IN pin hardware assignments see section 2-2-3 "Interfaces-GPI IN Connector."
Turn F1 at P NO. to select the pin you are making the assignment for. When pin 6 or
higher is selected, the screen will switch to the next page.
Turn F2 at FUNC to select the signal setting. The following FUNC settings are available.
Description
FUNC.
EFFECT Setting
Sets aspect ratio of the output signals.
1
ASPECT 4: 3
⇔
16: 9
(Open: 4: 3, Short: 16: 9)
Triggers an auto transition.
2 TRANS-TYPE
M/E1-BKGD-AUTO
3 TRANS-TYPE
M/E1-KEY1-AUTO
4 TRANS-TYPE
M/E1-KEY2-AUTO
5 TRANS-TYPE
M/E1-KEY3-AUTO
6 TRANS-TYPE
M/E2-BKGD
-AUTO
7 TRANS-TYPE
M/E2-KEY1-AUTO
8 TRANS-TYPE
M/E2-KEY2-AUTO
9 TRANS-TYPE
M/E2-KEY3-AUTO
10 TRANS-TYPE-M/E2-BLACK-AUTO
Changes transition type to FAM.
11 TRANS-TYPE
M/E1-BKGD
-FAM
12 TRANS-TYPE
M/E2-BKGD
-FAM
FUNCTION
GPI/TALLY GPI-IN
1
2
3
4
5
P NO.
1
EFFECT
2
D PRE
2
D PST
2
ENABLE
ON
2
2
2
2
2
TRANS-TYPE M/E1-BKGD AUTO
TRANS-TYPE M/E1-KEY1 AUTO
TRANS-TYPE M/E1-KEY2 AUTO
TRANS-TYPE M/E1-KEY3 AUTO
TRANS-TYPE M/E2-BKGD AUTO
2
2
2
2
2
FUNCTION
GPI/TALLY
1. TALLY COLOR
2. GPI IN
3. GPI OUT
4. TALLY1
5. TALLY2
SELECT
1
6. TALLY3
7. TALLY4
8. TALLY5
9. COLOR LOGIC