168
15-5. Data Recovery
In some cases, the settings may be inadvertently altered in the event recall or copying/swapping
operations. When this happens, the data recovery function can be used to restore to the state
before the data was recalled.
Immediately after the faulty recall, press the MU SETUP button to open the MU SETUP top
menu.
Turn F5 to set X-BUFF to ON. Then, press F5. The recalled values are canceled, and the
original values are restored.
15-6. Reboot and Initialization
MU Initialization
MU INIT in the MU SETUP - SYSTEM menu initializes all system setup data. You can select a
type of initialization from CUR, SYS and ALL by turning F6. Then press and hold down F6 at
least 1 sec to initialize data. A long beep sound will be heard when the data is initialized.
Setting
Description
CUR
All parameter data for MATT, TRANS,
PATTERN SELECT, KEY1, KEY2 and
KEY3 menus will be reinitialized.
Related data can be saved to event
memory.
SYS
Reinitialize only SYSTEM data
settings. Related data cannot be
event memory saved.
ALL
Reinitialize all system setup data
OU Initialization
OU INIT in the OU SETUP - OU MODE menu initializes only the settings data related to
operation unit. To do this, turn F6 to set OU INIT to ON, and then press and hold down F6 at
least 1 sec. A long beep sound will be heard when the data is initialized.
NOTE
Do not turn power OFF at your units during the OU re-initialization (while the OU SETUP
button flashing). Otherwise this may indicate initialization failure and cause the system to
malfunction.
MU SETUP
SYSTEM
FORMAT
1080
COARSE
0
MODE
RATE
59.94i
FINE
0
ASPECT
16:9
REF IN
H PHS
0
REF
IN
TRI_S
H PHS
0
1
BB
V PHS
0
MU
INIT
CUR
REF OUT
SC-PHASE
REF OUT
2
BB
MU SETUP
Ver.1.00.1
1.SYSTEM
2.INPUT
3.OUTPUT
4.MODE
5.MATT CLIP
SELECT
1
6.RS-422
7.NETWORK
8.DATE
X-BUFF
ON
REBOOT
OFF
OU SETUP
MODE(1/2)
BUTTON
CTRL
LIVE
TYPE
TYPE1
RATE
TYPE
FRM
BUZZER
VOLUME
16
JOY
STICK
NORMAL
TONE
NORMAL
SELECT
TIME
BRIGHT
NESS
10
MIN
5
SCREEN SAVER
SHIFT
SELECT
NORMAL
OU
INIT
ON
ON AIR
TYPE
M/E2