![Flowserve FlowAct 1502 Скачать руководство пользователя страница 74](http://html1.mh-extra.com/html/flowserve/flowact-1502/flowact-1502_user-instructions_2308443074.webp)
FlowAct Diaphragm Linear Actuator FCD VLENIMFACTA4 10/16
74
16 Torque Requirements
Torque Requirements for VALVE / ACTUATOR LOCK NUT (76, 256) per actuator size
Unit
253
503
701
1502
3002
Nm
Tighten the lock nut clockwise with a rounded chisel and a 1,5 kg (3.5 lbs) hammer before occurs the kickback
effect.
ft lb
Torque Requirements for COUPLING PARTs (345, 113, 249, 344, 240, 420, 214) per actuator size
Unit
253
503
701
1502
3002
Nm
Tighten the subordinate bolting properly by hand in accordance with the relevant technical standards.
ft lb
Torque Requirements for HEXAGON BOLT (334) per actuator size
Unit
253
503
701
1502
3002
Nm
n.n.
45
ft lb
33
Torque Requirements for SPECIAL NUT / STEM EXTENSION & STEM (348, 380) per actuator size
Unit
253
503
701
1502
3002
Nm
45
110
240
ft lb
33
81
177
Torque Requirements for CASING BOLTING (335 & 351 and 336 & 351, 209) per actuator size
Unit
253
503
701
1502
3002
Nm
20
ft lb
15
Torque Requirements for HEXAGON BOLTS (150) per actuator size
Unit
253
503
701
1502
3002
Nm
15
25
n.n.
ft lb
11
18
17 Lubricants
Use
Lubricant / Antiseize
WW (World Wide)
EU (European Union)
Standard,
from
-40°C to +80°C
-40°F to +176°F
Actuator O-Ring‘s (237, 247)
DOW Molykote 55 O-Ring Klüber Unisilikon L 250 L
Threads of the Actuator (107, 211, 250, 330, 334, 335, 336, 365) and Guide (247, 358)
Fastorq A/G
Klüberpaste 46 MR 401
Low temperature,
from
-60°C to -41°C
-76°F to -40°F
Actuator O-Ring‘s (237, 247) and Guide (247, 358)
Alcohol 96%
Threads of the Actuator (107, 211, 250, 330, 334, 335, 336, 365)
Fastorq A/G
Klüberpaste 46 MR 401