![Flowserve FlowAct 1502 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/flowserve/flowact-1502/flowact-1502_user-instructions_2308443026.webp)
FlowAct Diaphragm Linear Actuator FCD VLENIMFACTA4 10/16
26
Item #
Part
WW
EU
256
5.11
Lock Nut
372
6.30
Hex Nut
394
6.31
Carrier
Table 17: Handwheel parts
372
256
394
Actuator
HandWheel
Figure 14: Handwheel parts
Actuator with Handwheel - light
Spring-to-close
Disassembly instruction of the handwheel subas-
sembly
NOTICE
Limit disassembly only to necessary compo-
nents.
1. Fix the actuator on the assembly table, if this is not
already happened.
2. Loosen the hexagon nut (372) clockwise.
3. Loosen the carrier (394) counter-clockwise.
4. Loosen the lock nut (256) counter-clockwise.
NOTICE
Use a rounded chisel and a hammer.
5. Lift off and store the handwheel safely, lose no parts.
6. For disassemble the actuator subassembly see pages
22 - 23.
Reassembly instruction of the handwheel subas-
sembly
7. Lubricate the threads of the actuator with an appropri-
ate lubricant.
8. Mount the handwheel onto the actuator and tighten the
lock nut (256) clockwise.
NOTICE
Use a rounded chisel and a hammer.
9. Mount the hexagon nut (372) onto the actuator stem.
10. Mount the carrier (394) clockwise and lock the hexa-
gon nut (372).
11. Connect the actuator with the air supply, perform three
full strokes and check the free movement of the carrier.
NOTICE
The carrier must be able to move freely
without hitting in the end-positions.
12. Log the maintenance interval and the work performed.
13. The actuator subassembly is ready to be mounted on
the valve and the accessories attached.