![Flowserve FlowAct 1502 Скачать руководство пользователя страница 72](http://html1.mh-extra.com/html/flowserve/flowact-1502/flowact-1502_user-instructions_2308443072.webp)
FlowAct Diaphragm Linear Actuator FCD VLENIMFACTA4 10/16
72
Item #
Part
WW
EU
202
6.1
Diaphragm Casing (4x)
211
6.12
Stem
220
6.14
Disk (2x)
225
6.16
Diaphragm (2x)
227
6.15
Diaphragm Plate (2x)
228
6.13
Spacer Bushing (2x)
229
6.21
Actuator Spring
231
6.22
Distance Plate (2x)
253
6.8
Lower Guide Bushing
254
6.80
Plain Bearing (3x)
255
6.18
Thrust Washer (2x)
258
6.26
Vent Plug (2x)
272
6.17
O-Ring (2x)
273
6.11
Scraper Ring
275
6.10
O-Ring (3x)
276
6.9
O-Ring (4x)
279
6.46
O-Ring (24x)
326
6.23
Spring Adjusting Plate (2x)
334
6.45
Hexagon Bolt (24x)
335
6.3.1
Hexagon Bolt - short (40x)
336
6.3.2
Hexagon Bolt - long (8x)
337
6.5
Plain Washer (48x)
1)
339
6.25
Protection Sleeve (8x)
348
6.20
Stem
349
6.19
Lock Washer (2x)
351
6.4
Hexagon Nut (48x)
373
6.82
Intermediate Guide Bushing
374
6.47
Distance Bushing (2x)
380
6.81
Stem Extension
389
6.83
Upper Guide Bushing
1)
Alternatively, hex head assembled screws with captive flat washers are used for this application.
336
335
337
202
389
254
276
279
334
202
258
279
334
348
374
276
351
339
202
253
254
276
279
334
258
380
349
374
228
227
220
272
225
255
211
202
373
254
276
279
334
273
275
229
326
231
275
Table 39: Actuator parts
Figure 36: Actuator parts
44. Lubricate the new O-ring (272) with an appropriate lubricant.
45. Lower the distance bushing (374), spacer bushing
(228), disk (220), diaphragm plate (227),
diaphragm (225), O-ring (272), thrust
washer (255) and lock washer (349)
onto the stem extension (6.81).
NOTICE
Arrange the distance bushing like an
correctly wearing hat. The internal
stroke stop takes over the special nut.
46. Lubricate the thread of the stem extension (380) with
an appropriate lubricant.
NOTICE
The diaphragm plate should be posi-
tioned to the diaphragm with the aid
of the positioning template. Mark the position.
47. Fix the stem (211) with the stem clamping tool against
twisting.
48. Load the springs by tightening the stem (348) clock-
wise using a suitable torque wrench, see section 15
torque requirements.
NOTICE
We recommend you to use a hy-
draulic spring press, as a minimum
requirement a beam and threaded rods in 8.8 quality
(ISO 898-1) or higher as well as washers and nuts al-
ternatively.
49. Remove the stem clamping tool.
50. Install the diaphragm casing (203), positioning the
casing such that the air connections opposites.
51. Lubricate the threats of the long hexagon bolts (336) with
an appropriate lubricant and load the springs uniformly
in a clockwise sequence by tightening the long hexagon
bolts (336), plain washers (337) and hexagon nuts (351).
52. Install the short hexagon bolts (335), plain washers (337)
and hexagon nuts (351).
53. Tighten the nuts (351) using a crosswise pattern in
four steps, see section 15 torque requirements.
54. Install the protection sleeve (339).
55. Perform 3 full strokes and check the tightening of the
casing bolting.
56. Log the maintenance interval and the work performed.
57. The actuator subassembly is ready to be mounted on
the valve and the accessories attached.