flowserve.com
Item #
Part
WW
EU
256
5.11
Lock Nut
372
6.30
Hex Nut
394
6.31
Carrier
Table 18: Handwheel parts
Actuator
372
256
394
HandWheel
Figure 15: Handwheel parts
Actuator with Handwheel - light
Spring-to-open
Disassembly instruction of the handwheel subas-
sembly
NOTICE
Limit disassembly only to necessary compo-
nents.
1. Fix the actuator on the assembly table, if this is not
already happened.
2. Turn the handwheel counter-clockwise as long as it
reached the upper end-position.
3. Loosen the hexagon nut (372) clockwise.
4. Loosen the carrier (394) counter-clockwise.
5. Loosen the lock nut (256) counter-clockwise.
NOTICE
Use a rounded chisel and a hammer.
6. Lift off and store the handwheel safely, lose no parts.
7. For disassemble the actuator subassembly see pages
24 - 25.
Reassembly instruction of the handwheel subas-
sembly
8. Lubricate the threads of the actuator with an appropri-
ate lubricant.
9. Mount the handwheel onto the actuator and tighten the
lock nut (256) clockwise.
NOTICE
Use a rounded chisel and a hammer.
10. Mount the hexagon nut (372) onto the actuator stem.
11. Mount the carrier (394) clockwise and lock the hexa-
gon nut (372).
12. Turn the handwheel clockwise as long as it reached the
upper end-position.
13. Connect the actuator with the air supply, perform three
full strokes and check the free movement of the carrier.
NOTICE
The carrier must be able to move freely
without hitting in the end positions.
14. Log the maintenance interval and the work performed.
15. The actuator subassembly is ready to be mounted on
the valve and the accessories attached.