![Flowserve FlowAct 1502 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/flowserve/flowact-1502/flowact-1502_user-instructions_2308443045.webp)
FlowAct Diaphragm Linear Actuator FCD VLENIMFACTA4 10/16
45
flowserve.com
Item #
Part
WW
EU
202
6.1
Diaphragm Casing (2x)
209
6.6
Ring Nut
211
6.12
Stem
220
6.14
Disk
225
6.16
Diaphragm
227
6.15
Diaphragm Plate
228
6.13
Spacer Bushing
229
6.21
Actuator Spring
231
6.22
Distance Plate
253
6.8
Guide Bushing
254
6.80
Plain Bearing (2x)
255
6.18
Thrust Washer
258
6.26
Vent Plug
272
6.17
O-Ring
273
6.11
Scraper Ring (2x)
275
6.10
O-Ring (2x)
276
6.9
O-Ring (2x)
279
6.46
O-Ring (12x)
326
6.23
Spring Adjusting Plate
334
6.45
Hexagon Bolt (12x)
335
6.3.1
Hexagon Bolt - short (20x)
336
6.3.2
Hexagon Bolt - long (4x)
337
6.5
Plain Washer (24x)
1)
339
6.25
Protection Sleeve
348
6.20
Stem
349
6.19
Lock Washer
351
6.4
Hexagon Nut (24x)
374
6.47
Distance Bushing
389
6.83
Guide Bushing
1)
Alternatively, hex head assembled screws with captive flat washers are used for this application.
348
255
272
211
255
227
220
228
374
349
336
335
337
202
389
254
258
276
279
334
231
326
229
202
253
254
276
279
334
351
339
273
275
Table 29: Actuator parts
Figure 26: Actuator parts
with an appropriate lubricant then compress the springs
uniformly in a clockwise sequence by tightening the long
hexagon bolts (336), plain washers (337) and hexagon
nuts (351). Alternative method
see NOTICE
step 5.
24. Install the short hexagon bolts (335) and hexagon nuts
(351).
25. Tighten the nuts (351) using a crosswise pattern in
four steps.
26. Install the protection sleeve (339).
27. Reassemble the yoke and coupling parts, perform three
full strokes then check the tightening of the casing bolting.
28. Log the maintenance interval and the work performed.
29. The actuator subassembly is ready to be mounted on
the valve and the accessories attached.