![Flowserve FlowAct 1502 Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/flowserve/flowact-1502/flowact-1502_user-instructions_2308443054.webp)
FlowAct Diaphragm Linear Actuator FCD VLENIMFACTA4 10/16
54
Item #
Part
WW
EU
76
5.30
Adapter
107
5.32
Hex Bolt
118
5.31
Locking Plate
201
5.9
Yoke
213
5.7
Stroke Scale
214
5.20
Socket Head Screw (2x)
216
5.6
Stroke Indicator
240
5.5
Socket Head Screw (4x)
249
5.3
Actuator Coupling
256
5.11
Actuator Locknut
333
5.12
Plain Washer
334
5.19
Plain Washer (2x)
344
5.4
Lock Nut
345
5.1
Valve Coupling
420
5.8
Hex Bolt
201
213
333
420
214
Actuator
334
256
344
240
216
345
118
76
107
249
Table 34: Coupling parts
Figure 31: Coupling parts
Actuator with yoke
Spring-to-close or -open
Disassembly instruction of the yoke
NOTICE
Limit disassembly only to necessary compo-
nents.
1. Fix the actuator on the assembly table, if this is not
already happened, see also page 14 - 15.
2. Remove the socket head screws (214), plain washers
(334) and the stroke indicator (216).
3. Unlock the lock nut (344) counter-clockwise.
4. Loosen the actuator coupling (249) and lock nut (344)
clockwise.
5. We recommend you not to remove the actuator from
the yoke. If this is indispensable mark the position,
loosen the actuator locknut (256) clockwise and lift off
the actuator.
NOTICE
Use a rounded chisel and a hammer.
6. Store all coupling and yoke-parts safely, lose no parts.
7. For disassemble the attachments see pages 50 - 51
and for actuator subassembly see pages 42 - 49.
Reassembly instruction of the yoke
8. Lubricate the threads of the actuator and stroke cou-
pling-parts with an appropriate lubricant.
9. If necessary mount actuator onto the yoke (201) put
in line with the mark and tighten the actuator locknut
(256) counter-clockwise. The vent plug shall be at a
right angle to the yoke legs (see figure 31).
NOTICE
Use a rounded chisel and a hammer.
10. Screw in the lock nut (344) and the actuator coupling
(249) - screw-in depth once thread diameter - counter-
clockwise and fix it. Aligning the coupling parallel to
the yoke.
11. Mount the stroke indicator (216), plain washers (334)
and the socket head screws (214) clockwise.
12. Further reassembling steps are only possible with the
valve (see page 39).