Note: If after a few seconds, you do not see the recently-added hard disk drive in the disk summary,
the drive might not be seated properly. If this occurs, remove and reinsert the hard disk drive.
7.
Add the replacement drive (HD2 in the example) to the array by typing the following command:
tmsh modify sys raid array MD1 add HD2
The status of the replacement drive should change to replicating, and the STAT LED should change to
solid green. The replication process typically takes between 15 and 45 minutes.
8.
Attach the front bezel to the unit by grasping the bezel on either side using the indentations provided.
Note: Failure to use the indentations could result in pinched fingers.
50