see the
Traffic Management Shell (tmsh) Reference Guide
or the
BIG-IP
®
Systems: Getting Started
Guide
.
7.
Attach the front bezel to the unit by grasping the bezel on either side using the indentations provided.
Note: Failure to use the indentations could result in pinched fingers.
About hard disk drive replacement
The BIG-IP
®
11050 platforms support hard disk drive mirroring using RAID. You can add the replacement
hard disk drive sled that you received from F5 Networks to the system.
Identifying a faulty hard disk drive
Before you remove the hard disk drive from the system, you should first identify the faulty hard disk drive.
1.
Log on to the command line of the system using the root account.
2.
Type the following command to see the status of the drives:
tmsh show sys raid
A disk summary similar to the following displays:
---------------------
Sys::Raid::Array: MD1
---------------------
Size (MB)
279.4K
---------------------------------------------------------
Sys::Raid::ArrayMembers
Bay ID
Serial Number
Name
Array Member
Array Status
---------------------------------------------------------
1
WD-WCAT1E420107
HD2
yes
failed
2
WD-WCAT1E477614
HD1
yes
ok
----------------------------------------------------------------
Sys::Raid::Bay
Bay
Shelf
Name
Serial Number
Array Member
Array Status
----------------------------------------------------------------
1
1
HD2
WD-WCAT1E420107
yes
failed
2
1
HD1
WD-WCAT1E477614
yes
ok
3
-
-
-
-
-
4
2
SSD1
CVPO014601CG160AGN
no
undefined
4
1
SSD2
CVPO0146016R160AGN
no
undefined
--------------------------------------------------------------------------
Sys::Raid::Disk
Name
Serial Number
Array
Array Status
Model
Member
--------------------------------------------------------------------------
CF1
CB225535315009033B03
no
undefined
SILICONSYSTEMS INC 8GB
HD1
WD-WCAT1E477614
yes
ok
ATA
WDC WD3000BLFS-0
HD2
WD-WCAT1E420107
yes
undefined
ATA
WDC WD3202ABYS-0
SSD1
CVPO014601CG160AGN
no
undefined
ATA
INTEL SSDSA2M160
SSD2
CVPO0146016R160AGN
no
undefined
ATA
INTEL SSDSA2M160
3.
Make note of the bay number and serial number for the faulty hard disk drive.
Note: You can also locate the last seven digits of the serial number on the front of the drive. The serial
number is printed in its entirety on the labels, on top of the drive.
48
Platform Maintenance
Содержание BIG-IP 11050
Страница 1: ...Platform Guide 11050 MAN 0322 03 ...
Страница 2: ......
Страница 26: ......
Страница 39: ...Chapter 3 Platform Maintenance About platform maintenance ...
Страница 55: ...Figure 13 Airflow in the 11050 platform 55 Platform Guide 11050 ...
Страница 56: ......
Страница 63: ...Appendix C China RoHS Requirements Hazardous substance levels for China ...
Страница 65: ...Appendix D Repackaging Guidelines About repackaging the platform ...
Страница 67: ...5 Place the accessory box on the foam insert 6 Close and seal the shipping box 67 Platform Guide 11050 ...
Страница 68: ......