
152
EPICenter Software Installation and User Guide
The EPICenter Alarm System
Figure 65: The Synchronize RMON Rules window
You can resynchronize individual devices or all devices in a device group.
2
To select a device group, select Device Group from the pull-down list in the Source Type field. A list
of device groups will be displayed.
To select individual devices, select Devices in the Source Type field. A list is displayed showing all
the Extreme Networks devices managed by EPICenter.
3
To add a device or device group to the Selection list, select the device or device group and click
Add ->
. To add all devices or device groups in the list, click Add All ->.
4
To remove a device or device group from Selection list, select the item and click <- Remove. To
remove all devices or device groups, click <- Remove All.
5
Click Synchronize to initiate the synchronization process.
The Alarm Manager uses SNMP to retrieve configuration and status information from each selected
switch, and updates the database with that information.
6
The Synchronize function displays a dialog box with status or error information. Click OK to
continue.
7
Click Close to exit the Synchronize RMON Rules window.
Configuring Other SNMP Trap Events
There are a number of SNMP events that require configuration on the switch before they can be used in
EPICenter alarm definitions. If the configuration is not done on the switch, no trap events are generated,
and no EPICenter alarms for those events can occur. The Ping and OSPF traps fall into this category.
To configure the switch to send one of these traps, you must use a tool that allows you to set the value
of the appropriate SNMP variable. Tools such as SNMPc can be used to perform this function. The
following information assumes that you have a thorough understanding of SNMP and an appropriate
SNMP utility.
Refer to the appropriate MIBs for details of the variable settings:
•
Ping MIB: pingmib.mib (RFC 2925)
•
OSPF v2 MIB: RFC 1850 or RFC 1850t
Содержание EPICenter 4.1
Страница 20: ...20 EPICenter Software Installation and User Guide Preface ...
Страница 46: ...46 EPICenter Software Installation and User Guide EPICenter and Policy Manager Overview ...
Страница 190: ...190 EPICenter Software Installation and User Guide Configuration Manager ...
Страница 204: ...204 EPICenter Software Installation and User Guide Using the Interactive Telnet Application ...
Страница 242: ...242 EPICenter Software Installation and User Guide Using the IP MAC Address Finder ...
Страница 266: ...266 EPICenter Software Installation and User Guide Using ExtremeView ...
Страница 284: ...284 EPICenter Software Installation and User Guide Real Time Statistics ...
Страница 436: ...436 EPICenter Software Installation and User Guide Using the Policy Manager ...
Страница 454: ...454 EPICenter Software Installation and User Guide The ACL Viewer ...
Страница 468: ...468 EPICenter Software Installation and User Guide Troubleshooting ...
Страница 504: ...504 EPICenter Software Installation and User Guide EPICenter External Access Protocol ...
Страница 510: ...510 EPICenter Software Installation and User Guide EPICenter Database Views ...
Страница 522: ...522 EPICenter Software Installation and User Guide EPICenter Backup ...
Страница 526: ...526 EPICenter Software Installation and User Guide Dynamic Link Context System DLCS ...
Страница 546: ......