Setup & Operation 6. Options
80
C8 Rev.13
6.3 Tool Adapter (ISO Flange)
Using the tool adapter, you can mount the end effector whose dimensions are designed for
the ISO flange to the C8 series Manipulators.
Parts included
Qty.
ISO flange
1
Flange
1
Pin
2
Hexagon socket head screw with low head M5
×
10
6
Hexagon socket head screw M5
×
15
4
Dimensions of ISO flange
4-M5 depth 12
(at 90
°
pitch)
depth 5
depth 4
To mount the ISO flange
(1) Press-fit the pin to the Arm #6 end flange.
Pin projection : 4 mm from the flange
Pin
(2) Align the pin and the pin hole on the flange, and then
mount the flange.
Hexagon socket head screw: 4-M5
×
15
Hexagon socket
head screw 4-M5×15
Flange
(3) Press-fit the pin to the installed flange.
Pin protrusion: 4 mm from the flange
Pin
(4) Align the pin and the pin hole on the ISO flange, and
then mount the ISO flange.
Hexagon socket head screw
with low head: 6-M5
×
10
ISO flange
Hexagonal socket head
screw with low head
6 M5×10
Содержание C8 Series
Страница 1: ...Rev 13 EM208R4413F 6 Axis Robots C8 series MANIPULATOR MANUAL ...
Страница 2: ...Manipulator manual C8 series Rev 13 ...
Страница 8: ...vi C8 Rev 13 ...
Страница 14: ...Table of Contents xii C8 Rev 13 ...
Страница 16: ......
Страница 31: ...Setup Operation 2 Specifications C8 Rev 13 17 2 4 Outer Dimensions Unit mm 2 4 1 C8 A701 C8 ...
Страница 32: ...Setup Operation 2 Specifications 18 C8 Rev 13 2 4 2 C8 A901 C8L ...
Страница 33: ...Setup Operation 2 Specifications C8 Rev 13 19 2 4 3 C8 A1401 C8XL ...
Страница 49: ...Setup Operation 3 Environment and Installation C8 Rev 13 35 C8 A901 C8L ...
Страница 97: ...Maintenance This volume contains maintenance procedures with safety precautions for C8 series Manipulators ...
Страница 98: ......
Страница 183: ...Maintenance 4 Cable Unit C8 Rev 13 169 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Страница 184: ...Maintenance 4 Cable Unit 170 C8 Rev 13 ...
Страница 185: ...Maintenance 4 Cable Unit C8 Rev 13 171 ...
Страница 186: ...Maintenance 4 Cable Unit 172 C8 Rev 13 4 2 2 Power Cable C8 A701 C8 C8 A901 C8L ...
Страница 187: ...Maintenance 4 Cable Unit C8 Rev 13 173 C8 A1401 C8XL ...
Страница 188: ...Maintenance 4 Cable Unit 174 C8 Rev 13 C8 A701 C8 C8 A901 C8L C8 A1401 C8XL ...