Setup & Operation 2. Specifications
C8 Rev.13
25
*7: Conditions of Manipulator at measurement are as follows:
Operating conditions: Under rated load, 6 arms simultaneous motion, maximum speed,
maximum acceleration/deceleration, and duty 50% for C8/ C8L, 30% for C8XL.
Measurement point:
1000 mm apart from the rear of Manipulator
*8: The exhaust system in the Cleanroom-model Manipulator draws air from the base interior and arm cover
interior.
A crack or other opening in the base unit can cause loss of negative air pressure in the outer part of the
arm, which can cause increased dust emission.
Cleanliness level : C8, C8L ISO Class 3 (ISO14644-1)
: C8XL
ISO Class 4 (ISO14644-1)
Exhaust system
: Fitting for ø8 mm pneumatic tube
(Reference:
Setup & Operation: 3.6 User Wires and Pneumatic Tubes
)
60 L/min vacuum
Exhaust tube
: Polyurethane tube Outer diameter: ø8 mm (Inner diameter: ø5 to 6 mm)
ESD specification uses resin materials with antistatic treatment. This model controls adhesion of dust
due to electrification.
*9 Protection level for the protection-model Manipulators is IP67 (IEC standard). The Manipulators can be
used in environments where the possibility of dust, water, and water-soluble cutting oil falling of the
Manipulator exists.
However, please be careful of the following:
- The Manipulator is not rust-proofed. Do not use the Manipulator in environment where corrosive
liquids exist.
- Fluids that deteriorate the sealing materials, such as organic solvents, acids, alkalis, and chlorine
cutting fluids, cannot be used
- The Manipulator cannot be used for underwater operations.
- The Controller does not have protection features against the environment (Controller’s protection
level: IP20)
Make sure to install the system where environmental requirements for the Controller are satisfied.
<Reference>
- IP40 of IEC standard
[Protection level against ingress of solid objects]
Protection from entry by solid objects with a diameter or thickness greater than 1.0 mm.
[Protection level against ingress of liquids]
No protection
- IP67 of IEC standard
[Protection level against ingress of solid objects]
Totally protected against dust.
[Protection level against liquids]
Protection from ingress of water in harmful quantity when the Manipulator is immersed in
water for 30 minutes under the condition that the highest point of the Manipulator is located
0.15 m below the surface of the water and the lowest point is located 1 m below the surface
of the water. (Tested while the Manipulator is stopped.)
Содержание C8 Series
Страница 1: ...Rev 13 EM208R4413F 6 Axis Robots C8 series MANIPULATOR MANUAL ...
Страница 2: ...Manipulator manual C8 series Rev 13 ...
Страница 8: ...vi C8 Rev 13 ...
Страница 14: ...Table of Contents xii C8 Rev 13 ...
Страница 16: ......
Страница 31: ...Setup Operation 2 Specifications C8 Rev 13 17 2 4 Outer Dimensions Unit mm 2 4 1 C8 A701 C8 ...
Страница 32: ...Setup Operation 2 Specifications 18 C8 Rev 13 2 4 2 C8 A901 C8L ...
Страница 33: ...Setup Operation 2 Specifications C8 Rev 13 19 2 4 3 C8 A1401 C8XL ...
Страница 49: ...Setup Operation 3 Environment and Installation C8 Rev 13 35 C8 A901 C8L ...
Страница 97: ...Maintenance This volume contains maintenance procedures with safety precautions for C8 series Manipulators ...
Страница 98: ......
Страница 183: ...Maintenance 4 Cable Unit C8 Rev 13 169 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Страница 184: ...Maintenance 4 Cable Unit 170 C8 Rev 13 ...
Страница 185: ...Maintenance 4 Cable Unit C8 Rev 13 171 ...
Страница 186: ...Maintenance 4 Cable Unit 172 C8 Rev 13 4 2 2 Power Cable C8 A701 C8 C8 A901 C8L ...
Страница 187: ...Maintenance 4 Cable Unit C8 Rev 13 173 C8 A1401 C8XL ...
Страница 188: ...Maintenance 4 Cable Unit 174 C8 Rev 13 C8 A701 C8 C8 A901 C8L C8 A1401 C8XL ...