Proline Prosonic Flow 93C FOUNDATION Fieldbus
Technical data
Hauser
85
10.1.12 Certificates and approvals
CE mark
The measuring system is in conformity with the statutory requirements of the EC Directives.
Hauser confirms successful testing of the device by affixing to it the CE mark.
C-Tick mark
The measuring system complies with the EMC requirements of the "Australian Communications
and Media Authority (ACMA)".
Ex approval
Information on the currently available Ex-rated versions (ATEX, FM, CSA, etc.) can be supplied by
your Hauser Sales Center on request. All information relevant to explosion protection is
available in separate documents that you can order as necessary.
Certification
FOUNDATION Fieldbus
The flowmeter has passed all the test procedures implemented and has been certified and registered
by the Fieldbus Foundation. The device thus meets all the requirements of the following
specifications:
• Certified to FOUNDATION Fieldbus specification
• The flowmeter meets all the specifications of the FOUNDATION Fieldbus-H1.
• Interoperability Test Kit (ITK), revision 5.01:
The device can also be operated with certified devices of other manufacturers.
• Physical Layer Conformance Test by Fieldbus Foundation
Other standards and
guidelines
• EN 60529
Degrees of protection provided by enclosures (IP code).
• EN 61010-1
Safety requirements for electrical equipment for measurement, control and laboratory use.
• IEC/EN 61326
"Emission in accordance with Class A requirements".
Electromagnetic compatibility (EMC requirements).
• ANSI/ISA-S82.01
Safety Standard for Electrical and Electronic Test, Measuring, Controlling and Related
Equipment - General Requirements. Pollution Degree 2, Installation Category II.
• CAN/CSA-C22.2 No. 1010.1-92
Safety Requirements for Electrical Equipment for Measurement and Control and Laboratory Use.
Pollution Degree 2, Installation Category II.
• NAMUR NE 21
Electromagnetic compatibility (EMC) of industrial process and laboratory control equipment.
• NAMUR NE 43
Standardization of the signal level for the breakdown information of digital transmitters with
analog output signal.
• NAMUR NE 53
Software of field devices and signal-processing devices with digital electronics.
10.1.13 Ordering information
The Hauser service organization can provide detailed ordering information and
information on the order codes on request.
10.1.14 Accessories
Various accessories, which can be ordered separately from Hauser, are available for the
transmitter and the sensor
56.
Содержание Proline Prosonic Flow 93C
Страница 2: ......
Страница 90: ...www endress com worldwide BA00145D 06 EN 13 10 71121226 FM SGML6 0 ProMoDo...