Proline Prosonic Flow 93C FOUNDATION Fieldbus
Technical data
Hauser
79
Block information,
execution time
VCRs
Output data
Transducer Blocks / Analog Input Function Blocks
Block
Base index
Execution time [ms]
Functionality
Resource Block
400
–
Enhanced
"Flow" Transducer Block
2600
–
Vendor specific
"Diagnosis" Transducer Block
1600
–
Vendor specific
Transducer Block "Service"
1700
–
Vendor specific
"Display" Transducer Block
1800
–
Vendor specific
"Totalizer" Transducer Block
1900
–
Vendor specific
Analog Input function block 1
500
18
Standard
Analog Input function block 2
550
18
Standard
Analog Input function block 3
600
18
Standard
Analog Input function block 4
650
18
Standard
Analog Input function block 5
700
18
Standard
Analog Input function block 6
750
18
Standard
Analog Input function block 7
800
18
Standard
Analog Input function block 8
850
18
Standard
Discrete Output Function Block (DO)
900
18
Standard
PID Function Block (PID)
1000
25
Standard
Arithmetic Function Block (ARTH)
1100
20
Standard
Input Selector Function Block (ISEL)
1150
20
Standard
Signal Characterizer Function Block (CHAR)
1200
20
Standard
Integrator Function Block (INTG)
1250
18
Standard
VCRs (total 48)
Quantity
Permanent Entries
1
Client VCRs
0
Server VCRs
24
Source VCRs
23
Sink VCRs
0
Subscriber VCRs
23
Publisher VCRs
23
Block
Process variable
Channel parameter
(AI Block)
"Flow" Transducer Block
Average volume flow
25
Average sound velocity
28
Average flow velocity
29
Signal strength channel 1
30
Signal strength channel 2
31
"Totalizer" Transducer Block
totalizers1
7
totalizers2
8
Totalizer 3
9
Содержание Proline Prosonic Flow 93C
Страница 2: ......
Страница 90: ...www endress com worldwide BA00145D 06 EN 13 10 71121226 FM SGML6 0 ProMoDo...